Determining pierce height factor
Typical pierce height factor
See Figure 4-4 for sequence of events.
The Pierce Height Factor is a percentage of the cut height. The factor is entered into the THC pendant and the system
calculates the required pierce height. The Cut Height will be maintained until the Machine Acceleration Delay time has
elapsed, then Automatic Voltage Control will control torch height.
The default pierce height factor is 150%. Typically, this value is left at 150%.
EXAMPLE:
Cut Height
= 0.100 inch
Pierce Height Factor
= 150%
0.100 inch X 150%
=
0.150 inch*
Pierce Height
=
0.150 inch
*THC system performs this calculation.
Sets the lifter retract (homing) speed. This value is a compromise between
machine speed and the amount of weight on the lifter. At lower speeds, the
lifter is capable of lifting heavier loads.
Setpoint range:
Relative value between
1 (minimum) and 10 (maximum)
Homing Speed
Units can be set for inches or millimeters.
Inch or Metric Units
Sets a retract delay to allow time for the arc to ramp down and extinguish.
This time delay will start when the CNC removes the "Cycle Start" signal and
the plasma system is commanded to shutdown. After this programmed delay,
the torch will retract. Set this delay as short as possible, so that the
torch does not retract when the plasma arc is still active.
Retract Delay should be used on Hypertherm LongLife plasma systems.
Retract Delay
Содержание Command THC
Страница 61: ...SETUP CommandTHC for X Y Table Instruction Manual 3 7 5 Blank...
Страница 81: ...HD3070 SETUP CommandTHC for X Y Table Instruction Manual 3a 1 5 Section 3a HD3070 SYSTEM INTERCONNECTIONS...
Страница 88: ...HT2000 SETUP CommandTHC for X Y Table Instruction Manual 3b 1 6 Section 3b HT2000 SYSTEM INTERCONNECTIONS...
Страница 95: ...HT2000LHF SETUP CommandTHC for X Y Table Instruction Manual 3c 1 5 Section 3c HT2000LHF SYSTEM INTERCONNECTIONS...
Страница 102: ...HT4001 SETUP CommandTHC for X Y Table Instruction Manual 3d 1 5 Section 3d HT4001 SYSTEM INTERCONNECTIONS...
Страница 108: ...MAX100 SETUP CommandTHC for X Y Table Instruction Manual 3e 1 5 Section 3e MAX100 SYSTEM INTERCONNECTIONS...
Страница 113: ...MAX200 SETUP CommandTHC for X Y Table Instruction Manual 3f 1 6 Section 3f MAX200 SYSTEM INTERCONNECTIONS...
Страница 126: ...HT4400 SETUP CommandTHC for X Y Table Instruction Manual 3h 1 5 Section 3h HT4400 SYSTEM INTERCONNECTIONS...
Страница 135: ...HPR SETUP CommandTHC for X Y Table Instruction Manual 3i 1 9 Section 3i HPR SYSTEM INTERCONNECTIONS...
Страница 148: ...HPR SETUP 3i 14 CommandTHC for X Y Table Instruction Manual Figure 3i 14 Ohmic contact wire connection B B 11...
Страница 149: ...HSD130 SETUP CommandTHC for X Y Table Instruction Manual 3j 1 11 Section 3j HSD SYSTEM INTERCONNECTIONS...
Страница 188: ...MAINTENANCE CommandTHC for X Y Table Instruction Manual 5 15 6 Figure 5 7 Control board...
Страница 192: ...PARTS LIST CommandTHC for X Y Table Instruction Manual 6 3 10 Figure 6 2 THC control module interior...
Страница 220: ...CommandTHC for X Y Table Instruction Manual...