Hydronic P820 Скачать руководство пользователя страница 1

Hydronic Corporation 

 

Air Driven Hydraulic Pumps and Intensifiers 

 
 
 
 
 
 

P820 Installation, Use and Maintenance Manual 

 
 
 
 
 
 

Contents 

 
 
 
 
 
 

Introduction, Guarantee and Identification Plate 

 
 

Description, Startup Procedures 

 
 

Description of Working Parts, Storage and Disposal 

 

 

Fault Finding, Maintenance and Weights 

 
 

Spare Parts 

 
 
 
 
 

Hydronic Corporation, 2034 Fruit St, Algonac, MI 48001 United States of America 

 

(810) 794 4935 

www.hydroniccorp.com

 

Содержание P820

Страница 1: ...Manual Contents Introduction Guarantee and Identification Plate Description Startup Procedures Description of Working Parts Storage and Disposal Fault Finding Maintenance and Weights Spare Parts Hydronic Corporation 2034 Fruit St Algonac MI 48001 United States of America 810 794 4935 www hydroniccorp com ...

Страница 2: ...fy the pump model and serial number this will help us to respond quickly and effectively Guarantee Hydronic pumps are guaranteed both for the quality of materials used and for overall design The warranty runs for six months of normal use at eight hours per day and five days per week The warranty itself does not cover seals or defects arising out of operating with unsuitable fluids or at pressures ...

Страница 3: ...s 820 Installation Use and Maintenance Booklet 1 4 2021 Page 3 Identification Plate 1 Pump model and intensification ratio 2 Serial number pump 3 Maximum air pressure 4 Maximum working oil pressure allowed 5 Year of construction 1 2 3 4 5 ...

Страница 4: ...ed 1 2 should be used if the pump is to be run at higher speeds for greater flows It is advisable to use or maintain Hydraulic oil having viscosity of 150 to 250 SSU Oil temperature 32º F to 150º F Air temperature 40º F to 100º F Room temperature 40º F to 100º F Obstructive icing of the silencer may occur under certain temperature humidity conditions This can be remedied by the addition of antifre...

Страница 5: ...rom 30 psi to 100 psi the maximum hydraulic pressure can be adjusted by the ratio of the pump used As the hydraulic load of the circuit increases and the oil pressure rises the pump will slow down and eventually stop In this way the maximum load of the circuit will be maintained without air consumption Storage If the pump is to be kept out of use for a long period clean the pump in general and dra...

Страница 6: ...mps Intensifiers 820 Installation Use and Maintenance Booklet 1 4 2021 Page 6 Description of the standard pump components A Air valve B Oil outlet 8 SAE C Oil return 8 SAE D Oil filler plug E Oil level sight glass A B C D E ...

Страница 7: ... until primed and oil comes through to the oil output port Now shut off the air supply to the pump and securely connect the hydraulic circuit Switch on the air supply again and allow the pump to run in order to bleed any air out of the hydraulic circuit Pump features Standard manifolds and subplates are available with various configurations of SAE threaded ports for output and return as well as D0...

Страница 8: ...regulator dismantle and clean filter 2 Pump loses air from 2 1 Worn valve or seal 2 1 Replace seal or valve silencer when stalled 3 Excess oil leakage 3 1 Worn hydraulic seal 3 1 Replace seal from air silencer 4 Pump cycles without 4 1 Blocked oil intake 4 1 Clean out filter pumping oil 4 2 Bad connection 4 2 Check for bad connections on suction line or air leaks on suction line 5 Pump functions b...

Страница 9: ...es protection of the product Unpacking On receipt of the product open the packaging and remove the pump Take care not to damage any part of the pump Make an initial check on the pump for damage in transit In case of damage or if in doubt do not use the pump and contact Hydronic Corporation or your distributor The packaging plastic bags expanded polystyrene nails screws wood etc must not be left wi...

Страница 10: ...en on the nameplate D The part numbers E The quantity required F The name of the part All this data is given in the parts list A clear and correct statement of this data will allow our after sales service to respond quickly and appropriately Every spare part must be replaced by professionally qualified staff The manufacturer declines all responsibility for malfunctions or accidents deriving from a...

Страница 11: ...Hydronic Air Driven Pumps Intensifiers 820 Installation Use and Maintenance Booklet 1 4 2021 Page 11 Pump Exploded View ...

Страница 12: ...27 21 S820 XX N 102 3 031 0016 1 LOCK NUT 22 A820 XX N STF 5 042 0002 1 FLANGE 23 2 163 3 051 0078 1 O RING 2 162 3575 24 C00500 013 3 094 0008 4 SCREW M6x16 UNI5931 25 S820 XX N 43 3 045 0212 1 RING NUT M40x1 5 26 1 MANIFOLD WILL VARY DEPENDING ON OPTIONS 27 C02500 014 3 051 0109 2 O RING 2 14 2050 28 C00590 088 3 094 0010 2 SCREW M8x50 UNI5931 29 S820 XX N 29 3 094 0207 5 SCREW M8x25 UNI5739 30 ...

Страница 13: ...8 6187 P820 10 INCLUDED WITH S820 10 N 23 39 3 051 0014 2 O RING 2 217 4118 P820 20 INCLUDED WITH S820 20 N 23 39 3 051 0057 2 O RING 2 214 4100 P820 30 INCLUDED WITH S820 30 N 23 39 3 051 0010 2 O RING 2 212 4087 P820 40 INCLUDED WITH S820 40 N 23 40 S820 5 N 30 3 051 0096 2 PISTON SEAL P820 5 40 S820 10 N 30 3 051 0094 2 PISTON SEAL P820 10 40 S820 20 N 30 3 051 0092 2 PISTON SEAL P820 20 40 S82...

Страница 14: ...CER 1 2 50 S820 XX N 139 3 070 0068 1 SILENCER 1 2 51 S820 XX N 140 3 070 0028 2 PLUG MALE 1 4 52 A820 XX N 50 5 090 0025 1 SUCTION PIPE 53 A820 XX N 49 5 090 0024 1 DISCHARGE OIL PIPE 54 C02500 260 3 051 0237 1 O RING 2 260 4650 Seal Kits ITEM CODE CODE QTY DESCRIPTION S820 5 N SK 3 054 0028 1 S820 5 SEAL KIT S820 10 N SK 3 054 0029 1 S820 10 SEAL KIT S820 20 N SK 3 054 0030 1 S820 20 SEAL KIT S8...