Submersible Effluent Pump
SHEF50/SHEF100
NOTE! To the installer: Please make sure you providethis manual to the owner of the pumping equipment or tothe responsible party who maintains the system.
Pump Installation and Service Manual
Страница 1: ...luent Pump SHEF50 SHEF100 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...
Страница 2: ...per N E C ANSI NFPA 70 2001 Failure to heed above cautions could result in injury or death General Information Pump Warning 5 Do not remove ground pin from electrical plug 6 Do not use an extension cord 7 For proper automatic operation make sure the pump power cord is plugged into the piggyback 1ø only receptacle on the wide angle switch cord 3ø proper panel connections required 8 Connect to separ...
Страница 3: ...3 SHEF50 SHEF100 Typical Installation ...
Страница 4: ...if water traps in the pump and it cannot get out thus preventing pump from operating Hydromatic pumps have a small air vent hole in the impeller cavity to let out trapped air If this hole becomes plugged pump may air lock To break the air lock use a small screwdriver to clear hole in the impeller cavity As a secondary precaution in installations of this type 1 16 hole should be drilled in the disc...
Страница 5: ...motor assembly will have to be replaced Repeat for each leg or wire lead 8 Winding resistance test should be performed if the ground test is satisfactory Use ohmmeter with scale pointer set on R x 1 scale On this scale meter reads directly on ohms Always check the meter with leads together as described above under Ground Check test before making a reading of the winding Connect one meter lead to t...
Страница 6: ...sibly burned or if the ground resistance test or the winding resistance test has failed Note that the replacement stator must be of the same manufacture as the existing rotor or vice versa Replace the stator bolts 7 Remove the old O ring 19 regardless of condition and replace Place the new O ring over the seal plate shoulder Do not roll it If twisted water may enter chamber and cause failure 8 Rea...
Страница 7: ...ase for plugging 2 Pump head may be too high Pump cannot deliver water over SHEF50H 65 or SHEF100 90 vertical Horizontal distance does not affect pumping except loss due to friction 3 Inlet in pump base may be clogged Remove pump and clean out openings 4 Impeller or volute openings may be plugged or partially plugged Remove pump and clean per maintenance instructions 5 Pump impeller may be partial...
Страница 8: ... 1 7 00202 004 2 Volute Case SHEF100 1 9 00176 003 1 Screw Hex Hd 1 4 20x 50 5 10 00517 010 1 Screw Hex 3 11 09640 001 1 Impeller SHEF50 1 11 09640 002 1 Impeller SHEF100 1 12 08521 004 1 Bottom Plate SHEF50 1 12 08521 005 1 Bottom Plate SHEF100 1 13 01754 000 1 Locktite Sealant 14 14525A010 Shaft Seal 1 15 13562 000 1 Gasket SHEF50 1 15 13562 001 1 Gasket SHEF100 1 16 12845 001 1 Machine Screw 8 ...
Страница 9: ... Hd Cap 1 4 20x1 3 11 09640 001 1 Impeller SHEF50 1 11 09640 002 1 Impeller SHEF100 1 12 08521 004 1 Suction Bottom SHEF50 1 12 08521 005 1 Suction Bottom SHEF100 1 13 01754 000 1 Locktite Sealant 14 14525A010 Shaft Seal 1 16 13562 000 1 Gasket SHEF50 1 16 13562 001 1 Gasket SHEF100 1 19 00077 003 1 O Ring SHEF50 1 19 00077 003 1 O Ring SHEF100 2 20 12709 000 2 Adapter SHEF100 1 22 13216 001 5 Pow...
Страница 10: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...
Страница 11: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...
Страница 12: ...disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that does not conform to this contract or to this written warranty shall be to secure replacement thereof as aforesaid Hydromatic shall not in any event be liable for the cost of any labor expended on any s...