DESIGN BASIS AND DESIGN NOTES
Design
Configuration
Single Pass
Feedwater Source
TDS < 2000
System Recovery with Recycle
66+%
††††
System Pressure
100 PSI
†††
Rejection and Flow Rates
†††
Nominal Salt Rejection
95%
PRODUCT (purified water) Flow Rate
2.0+ GPM
††††
CONCENTRATE (drain) Flow Rate
0.80 GPM
CONCENTRATE (drain) Recycle Flow Rate
2.20 GPM
Connections
Feed Connection
1/2” QC
PRODUCT (purified water) Connection
1/2” QC
CONCENTRATE (drain) Connection
1/2” QC
Membranes
Membranes Per Vessel
1
Membrane Quantity
2
Membrane Size
4021
Vessels
Vessel Array
1:1
Vessel Quantity
2
Pumps
Pump Type
Multi
–Stage
Motor HP
1
RPM at 60HZ
3450
System Electrical
Controller
S100
High Voltage S Amp Draw
120V 1PH 60 HZ ,10.6A
System Dimensions
Approximate Dimensions
††
(L x W X H)
29.5” X 18.5” X 18”
Approximate Weight (Wet System)
145 lbs.
††
Does not include operating space requirements.
†††
System Pressure is variable due to water conditions. PRODUCT (purified water) flow will increase
at a higher temperature and decrease at a lower temperature.
††††
PRODUCT (purified water) flow and maximum recovery rates are based on feedwater conditions
as stated above. Do not exceed recommended PRODUCT (purified water) flow.
Содержание Hydroid
Страница 1: ...Reverse Osmosis User Manual 888 426 5644 info hydrologicsystems com ...
Страница 2: ...Hydroid Series User Manual 2 04 19 This page intentionally left blank ...
Страница 24: ...Hydroid Series User Manual 24 04 19 OPERATING LOG ...
Страница 29: ...Hydroid Series User Manual 29 04 19 CIRCUIT BOARD LAYOUT ...
Страница 34: ...Hydroid Series User Manual 34 04 19 HYDROID FLOW DIAGRAM ...
Страница 35: ...Hydroid Series User Manual 35 04 19 ELECTRICAL SCHEMATIC ...
Страница 38: ...Hydroid Series User Manual 38 04 19 ...