CONCENTRATE WATER (DRAIN) CONNECTION
Locate the 1/2” port on the right side of the system labeled
“CONCENTRATE” (drain). Run the drain line to an open drain in a free
and unrestricted manner (no back pressure).
ANY RESTRICTIONS OR BLOCKAGE IN THE DRAIN LINE
CAN CAUSE BACK PRESSURE, WHICH WILL INCREASE
THE SYST
EM’S OPERATING PRESSURE. THIS CAN
RESULT
IN
DAMAGE
TO
THE
SYSTEM’S
MEMBRANES AND COMPONENTS.
ELECTRICAL
The Hydroid system is 120 VAC 60 Hertz Single Phase, 10.6 amps, and
is equipped with an eight
–foot electrical cord.
Ensure that the electrical circuit supplying the system is compatible with the requirements of
the Hydroid.
TO REDUCE THE RISK OF ELECTRICAL SHOCK, THE INCOMING POWER
SUPPLY MUST INCLUDE A PROTECTIVE EARTH GROUND.
IT’S RECOMMENDED THAT THE SYSTEM HAVE A DEDICATED POWER
SOURCE
TANK
Hydroid systems may be connected to a bladder tank or a storage tank with a float valve. The
float valve shuts off the system when the tank is full, and opens when the water level in the
tank drops. Bladder tanks and storage tanks with float valves can be obtained by your local
dealer or distributor. If a storage tank with float valve is to be used, install it at this time.
THE SYSTEM MUST BE OPERATED ON PRE-FILTERED WATER ONLY.
Содержание Hydroid
Страница 1: ...Reverse Osmosis User Manual 888 426 5644 info hydrologicsystems com ...
Страница 2: ...Hydroid Series User Manual 2 04 19 This page intentionally left blank ...
Страница 24: ...Hydroid Series User Manual 24 04 19 OPERATING LOG ...
Страница 29: ...Hydroid Series User Manual 29 04 19 CIRCUIT BOARD LAYOUT ...
Страница 34: ...Hydroid Series User Manual 34 04 19 HYDROID FLOW DIAGRAM ...
Страница 35: ...Hydroid Series User Manual 35 04 19 ELECTRICAL SCHEMATIC ...
Страница 38: ...Hydroid Series User Manual 38 04 19 ...