background image

2

PRECAUTIONS

We do not recommend hooking any RO system up to your hot water tank lines because hot water tanks contain lots 

of minerals and the water can be too hot. 

A safe way to increase temperature is with an on demand or flash style 

water heater set at below 100°F (37.7°C). For people with adequate pressure but decreased water temperature a 

flash water heater is a great way to increase flow rates.

 

6

Do not use this product to make safe drinking water from non-potable water sources. 

Do not use the system on microbiologically unsafe water, or water of unknown quality 

without adequate disinfection before or after the system.

 

6

Temperature of the water supply to the 

 

must be between 40°F–100°F 

(4°C–38°C). 

Do not install on hot water lines.

 

6

High levels of certain contaminants in the incoming water may prematurely foul the 

membranes and/or the pre-filter. Softened water is recommended for optimal system 

performance and RO membrane life.

 

6

The black drain line must be unrestricted at all times.

 

6

Keep out of direct sunlight or high intensity lights, which degrade the housing and 

fittings over time. Protect unit against freezing to prevent cracking of the filter housing 

and water leakage. 

Replace housings every three years. 

 

6

When replacing filter cartridges use the filter wrench to remove housing. Do not use 

the wrench to tighten the housings. Hand tighten the housings only. Take care not to 

over-tighten.

 

6

Do not install where leakage or failure may cause damage to property.

 

6

If you are going to store or not use your 

 for an extended period of time  

(2 weeks+), it is recommended that you remove your membranes, seal them in plastic 

and put in refrigerator. Once removed, membranes are no longer under warrenty.

 

6

Keep the lengths of tubing short. Longer lengths of tubing will decrease inlet pressure 

and ultimately system performance. 

 

6

Do not use grease containing petroleum products.

 

6

When the system is initially turned on, water may temporarily sputter until all the air 

is purged. Allow up to 24 hours for any trapped air noise in the system to subside.

 

6

The flow rate of product water can drastically decrease due to low psi and low 

temperature, especially in the winter. In some cases with cold temperature and/or low 

pressure predicted flow rate can drop by as much as 50% or more. A combination of 

cold water and low pressure can drop flow rates even further. This is the case with all 

RO technology and is not unique to the 

. The ratio of wastewater to product 

water can also get drastically worse due to low pressure and low temperature. You can 

overcome some of these issue by increasing pressure with our optional booster pump 

(

HL 29014 

See pg. 12) or by increasing inlet temperature. 

Содержание EvolutionRo

Страница 1: ...BUILT IN THE U S A BUILT IN THE U S A USER MANUAL...

Страница 2: ...SCRIPTION TABLE OF CONTENTS The is a customized Reverse Osmosis water filter that is made in the USA This system is capable of reducing up to 95 of most contaminants This system is designed and built...

Страница 3: ...g filter cartridges use the filter wrench to remove housing Do not use the wrench to tighten the housings Hand tighten the housings only Take care not to over tighten 6 Do not install where leakage or...

Страница 4: ...life of the membranes will vary based on feed water quality Product water should be tested periodically to verify the membranes are performing properly For most applications the membranes should be r...

Страница 5: ...te White Feed Fitting X1 6 Blue Product Water Fitting X1 7 Orange 1 1 Ratio Drain Fitting X1 8 Green 2 1 Ratio Drain Fitting X1 9 Lock Bar X1 10 Pressure Gauge w Tee Fitting X1 11 Support Leg Housing...

Страница 6: ...OU MUST REMOVE MEMBRANES FIRST Afterwards go back to STEP 9 to install the two membranes IMPORTANT BEFORE YOU START To ensure optimal efficiency the carbon filter MUST BE FLUSHED FOR 10 MINUTES PRIOR...

Страница 7: ...membrane Do not rock membrane back and forth to install Repeat this step for second membrane hose inlet fitting onto other end of tubing This fitting is compatible with garden hoses and hose bibs STE...

Страница 8: ...luminum Al 3 97 98 Ammonium NH4 85 95 Arsenic As 90 95 Borate B4O2 2 30 50 Boron B 60 70 Bromide Br 93 96 Cadmium Cd2 93 97 Calcium Ca 2 95 98 Chloride Cl 92 98 Chromate CrO4 2 85 95 Copper Cu2 96 98...

Страница 9: ...one of the industry s most reliable and highest performing membranes that deliver consistent performance and quality Advanced membrane technology and manufacturing processes allow these membranes to...

Страница 10: ...urized before removing fittings then push in the collet evenly against the face of the fitting With the collet held in this position the tube can be removed by simply pulling You can use a collet rele...

Страница 11: ...specified operating parameters listed on page 8 Do not operate unit if incoming pressure exceeds 80 psi or there is problem with water hammer or pressure spikes The manufacturer believes the informati...

Страница 12: ...verse Osmosis technology Since RO water is almost pure H2O and has no ability to buffer pH the actual pH reading will not be accurate until you add minerals back Q Why are both the 1 1 and 2 1 Flow Re...

Страница 13: ...Wall Mount Bracket HL 10057 Stainless steel heavy duty bracket to mount your system on the wall Drain Saddle HL 10055 The optional drain saddle is an alternative way to run your drain line OPTIONS Flo...

Страница 14: ...FILTER REPLACEMENT LOG MEMBRANE DATE CARBON FILTER DATE...

Страница 15: ...USER NOTES...

Страница 16: ...370 Encinal Street Suite 150 Santa Cruz CA 95060 ph 888 426 5644 fax 831 336 9840 techsupport hydrologicsystems com hydrologicsystems com ACCREDITED BUSINESS...

Отзывы: