1

Description, Table of Contents ................................................................................p 1 

Precautions ..........................................................................................................p 2

Filter Replacement Schedule ..................................................................................p 3

Includes ..............................................................................................................p 4

Installation .......................................................................................................p 5–6

Performance and Dimensions .................................................................................p 7

Component Specs ................................................................................................p 8

Quick Connect Fittings ..........................................................................................p 9

Warranty and Support ........................................................................................p 10

Troubleshooting .................................................................................................p 11

Options ............................................................................................................p 12

Filter Replacement Log ........................................................................................p 13

User Notes ........................................................................................................p 14

DESCRIPTION

TABLE OF CONTENTS

The 

 

is a customized Reverse Osmosis water filter that is made in the USA. This system 

is capable of reducing up to 95% of most contaminants. This system is designed and built for use 

with hydroponic or horticultural applications. This system is built to give the maximum amount 

of flow from the membrane while sending less wastewater to the drain, compared to similar RO 

filters. Please read the following setup and maintenance guide to get the maximum results from 

your filter.

Содержание EvolutionRo

Страница 1: ...BUILT IN THE U S A BUILT IN THE U S A USER MANUAL...

Страница 2: ...SCRIPTION TABLE OF CONTENTS The is a customized Reverse Osmosis water filter that is made in the USA This system is capable of reducing up to 95 of most contaminants This system is designed and built...

Страница 3: ...g filter cartridges use the filter wrench to remove housing Do not use the wrench to tighten the housings Hand tighten the housings only Take care not to over tighten 6 Do not install where leakage or...

Страница 4: ...life of the membranes will vary based on feed water quality Product water should be tested periodically to verify the membranes are performing properly For most applications the membranes should be r...

Страница 5: ...te White Feed Fitting X1 6 Blue Product Water Fitting X1 7 Orange 1 1 Ratio Drain Fitting X1 8 Green 2 1 Ratio Drain Fitting X1 9 Lock Bar X1 10 Pressure Gauge w Tee Fitting X1 11 Support Leg Housing...

Страница 6: ...OU MUST REMOVE MEMBRANES FIRST Afterwards go back to STEP 9 to install the two membranes IMPORTANT BEFORE YOU START To ensure optimal efficiency the carbon filter MUST BE FLUSHED FOR 10 MINUTES PRIOR...

Страница 7: ...membrane Do not rock membrane back and forth to install Repeat this step for second membrane hose inlet fitting onto other end of tubing This fitting is compatible with garden hoses and hose bibs STE...

Страница 8: ...luminum Al 3 97 98 Ammonium NH4 85 95 Arsenic As 90 95 Borate B4O2 2 30 50 Boron B 60 70 Bromide Br 93 96 Cadmium Cd2 93 97 Calcium Ca 2 95 98 Chloride Cl 92 98 Chromate CrO4 2 85 95 Copper Cu2 96 98...

Страница 9: ...one of the industry s most reliable and highest performing membranes that deliver consistent performance and quality Advanced membrane technology and manufacturing processes allow these membranes to...

Страница 10: ...urized before removing fittings then push in the collet evenly against the face of the fitting With the collet held in this position the tube can be removed by simply pulling You can use a collet rele...

Страница 11: ...specified operating parameters listed on page 8 Do not operate unit if incoming pressure exceeds 80 psi or there is problem with water hammer or pressure spikes The manufacturer believes the informati...

Страница 12: ...verse Osmosis technology Since RO water is almost pure H2O and has no ability to buffer pH the actual pH reading will not be accurate until you add minerals back Q Why are both the 1 1 and 2 1 Flow Re...

Страница 13: ...Wall Mount Bracket HL 10057 Stainless steel heavy duty bracket to mount your system on the wall Drain Saddle HL 10055 The optional drain saddle is an alternative way to run your drain line OPTIONS Flo...

Страница 14: ...FILTER REPLACEMENT LOG MEMBRANE DATE CARBON FILTER DATE...

Страница 15: ...USER NOTES...

Страница 16: ...370 Encinal Street Suite 150 Santa Cruz CA 95060 ph 888 426 5644 fax 831 336 9840 techsupport hydrologicsystems com hydrologicsystems com ACCREDITED BUSINESS...