Connecting QC Fittings:
Push tubing firmly into the fitting, all the way until the tube stops. The collet (gripper) has stainless
steel teeth which hold the tube firmly in position while the O-ring provides a leak proof seal. Pull
tubing to check for security. If some tube pulls out, then push it all the way in again until it stops. It
is good practice to test the system prior to leaving site and/or before use.
Disconnecting QC Fittings:
Ensure system is depressurized before removing fittings then push in the collet evenly against the
face of the fitting. With the collet held in this position the tube can be removed by simply pulling.
You can use a collet release tool (
HL 24010,
available from your dealer). The fitting can then be
re-used. If the tubing has been removed several times you may see score marks on the ends, and
this can lead to leaks. It is best to cut the end off of the tubing with a sharp blade, being careful to
cut straight across. Any angle to the cut can cause a leak.