HydroCheck HC7000 Скачать руководство пользователя страница 1

Questions or Comments Contact Us At: 

www.hydrocheckproducts.com or [email protected] or 877-225-2124

 

 
900-003 Rev F (Front) 

 

Flotec and Tempest are Registered Trademarks of Pentair, Inc 

 
 
 
 

Installation Instructions 

 

Operational Overview 

The HC7000 Electronic Utility Pump Switch is specially designed to control the on and off operation of small utility 
pumps. 
 
The HC7000 will turn on the pump when the water level reaches the sensor.  It will keep the pump running until the 
water level drops to the point where the pump loses suction.  

Note that it must take at least 5 seconds of 

running before losing suction for the pump to shut off correctly.  

It then turns the pump off and waits for the 

next cycle to begin.   To help protect the pump from damage due to air lock conditions, the HC7000 will turn the 
pump off for 10 seconds if the water level doesn’t drop below the level of the sensor after running for 60 seconds.  
An alarm will sound (3 beep pattern) if this occurs. 
 

 

Step-by-Step Installation 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

How the Sensor Works:

 

 

The sensor detects the presence of water by using a continuity circuit, which, when the tip 
of the sensor is in water, allows a small voltage to flow from the sensor, through the water, 
to ground.  When no water is present, the circuit is broken and no voltage flows.  Normally, 
the pump provides the ground needed for the continuity circuit, but occasionally it won’t.  
When this happens, it is necessary to provide a ground for the sensor to work.  This can 
be done by taking a length of wire (14 AWG) with a couple of inches of insulation stripped 
off at both ends.  Secure one end of the wire around a water pipe or electrical conduit.  
Place the other end under the pump, which will hold it in place. 
 

Step 2 

Plug the pump motor into control 
module.  Note that the HC7000’s 
output is rated for a maximum of 120 
VAC, ¾ HP/13.8 Amps (standard for 
most utility pumps). 

Step 1 

Plug the HC7000’s control module 
into the 120VAC outlet.  It will beep 
once to tell you it’s ready to go and 
the LED will illuminate RED.  RED 
indicates the output is off.  GREEN, or 
flashing GREEN, indicates the output 
is on.  

Note that this product is not 

rated for outdoor use. 

Step 3 

Attach the sensor to the pump with the 
supplied tie-wrap at the level where you 
want the pump to turn on.  The sensor can 
be set at any level, but most pumps need 
a minimum water depth before they should 
be turned on.  Consult your pump’s 
owner’s manual for this requirement.  .  

The sensor should be positioned 
so that the pump will run for at 
least 5 seconds before sucking air

.   

Step 4 

Important!  

Test your installation before 

leaving it for unattended operation.

  For best 

results, make sure to use a high quality hose that is 
as short as possible, kink resistant and is at least 
5/8” in diameter. 

® 

Отзывы: