49-20-0312 - www.hydroair.dk – November 2009 

 

ELECTRONIC CONTROL BOX 20-0312 

 

Specifications 

Rated voltage: 

230 VAC, 50Hz, single phase 

Rated power: 

2300W  

Rated current: 

10 A 

 
Output A: 

Max. 900W 

Output B: 

Max. 2300W   

Output C: 

Max. 2300W 

 
The total sum of the loads must not exceed the rated power and current.  
 

Dimensions & temperature 

Weight: 

 

0.9 

kg 

     

Length: 200 

mm 

 

Width: 150 

mm 

Depth: 

 80 mm 

Operating temperature:  0 to 50°C 
Storage temperature: 

-20 to 50°C 

 

Important 

This control box is not suitable for medical use. Follow the directions for installation and connection. We reserve 
the right to change the product and the specification without notice.  
 

Safety rules 

A. 

Locate the box in a dry area with good ventilation. 

B. 

The box must be situated at least 3 cm above the ground floor. 

C. 

Before cleaning, servicing, exchanging of parts or accessories or checking up on various disturbances, the 
mains have to be cut off. 

D. 

Make sure that there are no unconnected wires and cables inside the box. 

E. 

Cables and wires must be as short as possible inside and outside the box. 

F. 

The box is protection Class I. It has to be connected with cables according to the instructions from EN 
60335-1 and EN 60335-2-60. It is recommended that you consult a state registered electrician. The supply 
cable has to be minimum type H05VV-F; 3G1.5 mm

2

G. 

Keep at all time minimum 20 mm distance between high and low Voltage cables. 

H. 

In order to separate the box from the mains you must install a suitable ground fault circuit interrupter with at 
least 3 mm break distance on each terminal in the present electrical installation. 

I. 

The mounting is to be made in such a way that it is not possible to touch the electric parts. 

J. 

The electric parts have to be mounted in such a way that they cannot fall into the bathtub. 

K. 

Instruments of Class I must be connected to a permanent installation. 

L. 

Be aware that some countries have requirements about power indication. 

M. 

Tighten all cable glands sufficient by means of a tool to ensure that the Ingres protection is IPX5 and to 
ensure that the cables are fixed in position and protected for physical traction and pressure. 

N. 

If not all cable outlets are used, the cable gland(s) in question has to be changed to dummy plug(s) of the 
same dimension to ensure that the Ingres Protection still is IPX5. 

O. 

This appliance is not intended for use by persons, including children with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision or in-
struction concerning use of the appliance by a responsible for their safety. 

P. 

Children should be supervised to ensure that they do not play with the appliance.  

 

Содержание 20-0312

Страница 1: ...d electrician The supply cable has to be minimum type H05VV F 3G1 5 mm2 G Keep at all time minimum 20 mm distance between high and low Voltage cables H In order to separate the box from the mains you must install a suitable ground fault circuit interrupter with at least 3 mm break distance on each terminal in the present electrical installation I The mounting is to be made in such a way that it is...

Страница 2: ...is connected to the system Water level indicator Pump LED will flash every second to indicate adequate water in the bathtub Function indicator If pump blower or light is activated LED for each function will light up Dry blowing indicator Blower LED will flash during the automatic dry blowing program Automatic dry blowing program The program will start after water level sensor indicates low level A...

Страница 3: ... 20 0312 Connection diagram MAINS A HEAT B C D CONTROL PANEL LEVEL SAFETY LED LED LED LED LED GND E F G H BLUE BLACK BROWN AUX IN MAX 10A MAX 10A I BLUE YELLOW GREEN GREY RED GREY PINK BLUE RED WHITE BROWN PURPLE BLACK 23 3669 LIGHT PUMP PUMP LIGHT AIR AIR UP DOWN ...

Страница 4: ...se I og må kun elektrisk forbindes i overensstemmelse med EN 60335 1 og EN 60335 2 60 Det anbefales at De rådfører Dem med en autoriseret elinstallatør Tilslutningskablet skal som minimum være type H05VV F 3X1 5 mm2 G Der skal være en afstand på mindst 20 mm mellem stærk og svagstrømskabler H Boksen skal adskilles fra nettet af en kontakt med en brydeafstand på min 3 mm på hver pol I Installeringe...

Страница 5: ...m indikation Pumpe dioden vil blinke hver 10 sekund for at indikere der er strøm på systemet Vandstandsindikation Pumpe dioden vil blinke hvert sekund for at indikere korrekt vandstand i karret Funktionsindikation Når pumpe blæser eller lys er aktiveret vil tilhørende diode lyse Tørblæsningsindikation Når tørblæsningsprogrammet kører vil dioden for blæser blinke Automatisk tørblæsningsprogram Akti...

Страница 6: ...OL BOKS 20 0312 Tilslutningsdiagram MAINS A HEAT B C D CONTROL PANEL LEVEL SAFETY LED LED LED LED LED GND E F G H BLUE BLACK BROWN AUX IN MAX 10A MAX 10A I 23 3669 LIGHT PUMP PUMP LIGHT AIR AIR UP DOWN BLÅ RØD SORT HVID BRUN LILLA GRÅ PINK GRÅ RØD BLÅ GUL GRØN ...

Отзывы: