10094778 Rev B 11/10 © Hydro Systems Company, Inc. 2010 HydroSystemsCo.com Toll Free: 1.800.543.7184
1
This guide contains instructions for installing, programming, and troubleshooting
the AutoDose™ Dispensing System. Throughout the guide, the following icons are
used to indicate the model(s) to which each step pertains.
AutoDose
™
Automatic Dispensing System
The AutoDose
TM
is a battery or A/C-powered peristaltic pumping dispenser that runs automatically at preset times as
programmed with an electronic timer / control. Product operates reliably and consistantly, even in demanding environments.
!
Please use this equipment carefully and
observe all warnings and cautions.
ALWAYS
observe safety and handling instructions of
the chemical manufacturers.
ALWAYS
direct discharge away from you or other
persons or into approved containers.
ALWAYS
dispense cleaners and chemicals in accordance
with manufacturer’s instructions. Exercise CAUTION
when maintaining your equipment.
KEEP
equipment clean for proper operation.
WEAR
protective clothing and eyewear when working
in the vicinity of all chemicals, filling or emptying
equipment, or changing tubes.
ALWAYS
re-assemble equipment according to
instruction procedures. Be sure all components are
firmly screwed or latched into position. Ensure that
hoses and electrical wires are properly placed and not
kinked or pinched.
ONLY USE ALKALINE BATTERIES.
Tube life will vary depending on the type of treatment
product used. To prevent emergency service, schedule
replacement at least once per year.
NOTE
:
The batteries should be scheduled for periodic
replacement. Using a total of 40 running (pumping)
hours, create a schedule for servicing the unit and
changing the batteries. Maintaining the power source
as such will help to provide the proper dosing by
providing a more consistent pumping rate.
Models:
Mounts:
Power:
Pail Mount
(3.5 – 5 gal pail)
8 D-cell batteries
Wall Mount
8 D-cell batteries
Wall Mount
A/C Power or 8 D-cell batteries
1170
1180
1190
AutoDose™ Dispenser Specifications:
PUMP
Flow Rate
Approx 3.5 oz / min
Tube Material
EPDM
Inlet Vacuum
20+ in Hg
Outlet Pressure
20 psi
SYSTEM CABINET
Material
Polypropylene and ABS
Size (Model 1170)
Approx. 7 3/4” tall X 14” diameter
(does not include container 1170 model system sits on)
Size (Models 1180 and 1190)
4 3/4” X 6 3/4” X 8 1/3”
PROGRAMMABLE TIMER / CONTROL
Program Duration
Daily / Weekend / Week Days/Special
Maximum # of Events
24
Dispense Amount per Event
1 oz – 30 oz (dispensed in 1 oz increments)
or 30 – 900 ml (dispensed in 30 ml increments)
This package should contain:
•
One AutoDose
TM
dispenser
INSTALL PACKAGE CONTAINING:
•
Ceramic weight and strainer for inlet tubing
•
Polyethylene tubing (10 ft)
•
Cable ties
•
Mounting Bracket (Some Models)
•
AC Adapter (Some Models)
•
Injection Fitting