Troubleshooting Chart:

* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are

exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove
an eductor located in the cabinet, firmly grasp vacuum breaker and unthread eductor. Replace in same manner.
Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit.
Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then
flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into
concentrate.

1. No discharge

a. No water

a. Open water supply

b. Magnetic valve not functioning

b. Install valve parts kit

c. Excessive water pressure

c. Install regulator if water pressure exceeds

4.3 bar (flowing)

d. Eductor clogged

d. Clean* or replace

2. No concentrate draw

a. Clogged foot valve

a. Clean or replace

b. Metering tip or eductor has

b. Clean (descale)* or replace

scale build-up

c. Low water pressure

c. Minimum 1.43 (with water running)

required to operate unit properly

d. Discharge tube(s) not in place

d. Push tube firmly onto eductor discharge

or flooding ring missing from

hose barb; be sure inner discharge tube

inner discharge tube

is installed and has flooding ring.

e. Concentrate container empty

e. Replace with full container

f. Inlet hose barb not screwed

f. Tighten, but do not overtighten

into eductor tightly

g. Clogged water inlet strainer

g. Disconnect inlet water line and clean

strainer

h. Selector out of position

h. Assure selector is in position desired

3. Excess concentrate draw

a. Metering tip not in place

a. Press correct tip firmly into barb on

eductor

b. Chemical above eductor

b. Place concentrate below the eductor

4. Failure of unit to turn off

a. Water valve parts dirty or

a. Clean* or replace with valve parts kit

defective

b. Magnet doesn't fully return

b. Make sure magnet moves freely.

c. Push button stuck

c. Remove button and clean cabinet/button

to remove any dirt lodged in slide recess

5. Excess foaming in discharge a. Air leak in pick-up tube

a. Put clamp on tube or replace tube if brittle

b. Inner discharge tube not in place

b. Install inner discharge tube

Solution

Cause

Problem

10084450

Hydro Systems Europe Ltd

, Unit 3, The Sterling Centre, Eastern Road, Bracknell, Berks RG12 2PW  UK

Tel: +44 (0)1344 48 88 80
Fax: +44 (0)1344 48 88 79
www.hydrosystemseurope.com

Содержание AccuDose 3876GB-2

Страница 1: ...VE STRAINERSPERIODICALLYFORCLOGGING CLEANIFNECESSARY 6 A short discharge tube is used with the 4 LPM eductor selector valve minimum tube length is 20 cm for correct operation A longer tube 1 2m is used with the 16 LPM eductor Slide end of tube with flooding ring over eductor discharge outlet The hose hook supplied may be installed on the long tube to allow it to conveniently hang from dispenser wh...

Страница 2: ... concentrate X 1 If the test does not yield the desired ratio choose a different tip and repeat the test Alternative methods to this test are 1 pH using litmus paper and 2 titration Contact your concentrate supplier for further information on these alternative methods and the materials required to perform them AccuDose Parts Diagram 5 7 8 4 2 3 1 6 1 238100 Strainer washer 2 10082835 Swivel collar...

Страница 3: ...are for 16 LPM discharge tubes 17 10061100 Support 18 10080920 Selector valve replacement kit e Suction stub f O ring g selector valve assembly 19 690014 Metering tip kit 20 500870 Tubing 6mm x 2 1 m 21 509900 Weight 22 10076301 Foot valve Viton EPDM also available Order 10076302 NOT SHOWN 641750 Security screws for cabinet sides Description Part No Key 9 10 11 12 13 14a 18 19 17 19 e 15a 22 21 20...

Страница 4: ...water running required to operate unit properly d Discharge tube s not in place d Push tube firmly onto eductor discharge or flooding ring missing from hose barb be sure inner discharge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged...

Отзывы: