background image

Metering Tip Selection:

The final concentration of the dispensed solution
is related to both the size of the metering tip
opening and the viscosity of the liquid being
siphoned. For water-thin products, the chart at
right can be used as a guideline. If product is
noticeably thicker than water, consult the Mea-
surement of Concentration Procedure below to
achieve your desired water-to-product ratio. Be-
cause dilution can vary with water temperature
and pressure, actual dilution achieved can only
be ascertained by using the Measurement of
Concentration Procedure. The clear, undrilled tip
is provided to permit drilling to size not listed
should you need a dilution ratio that falls between
standard tip sizes.

NOTE:

 A 4 LPM eductor is grey; a 16 LPM eductor

is yellow. Refer to parts diagram if unfamiliar with
names of system components.

Measurement of Concentration:

You can determine the dispensed water-to-prod-
uct ratio for any metering tip size and product
viscosity. All that is required is to operate the
primed dispenser for a minute or so and note two
things: the amount of dispensed solution, and
the amount of concentrate used in preparation of the solution dispensed. The water-to-product ratio is then calculated
as follows:

Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount of Concentrate Drawn

Amount of Concentrate Drawn

Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If  the test does not yield the desired ratio, choose
a different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration. Contact
your concentrate supplier for further information on these alternative methods and the materials required to perform
them.

AccuDose Parts Diagram:

5

7

8

4

2

3

1

6

1

238100

Strainer washer

2

10082835 Swivel collar (molded)

3

10082806 Swivel stem (molded)

4

10075911 Hex nipple
10075950 O-ring (two per nipple)

5

10075925 Pipe plug

6

10080710 Button, dark grey (standard)
10080711 Button, sky blue
10080712 Button, red
10080713 Button, green
10080714 Button, light grey
10080715 Button, yellow

7

10080895 Cabinet

8

10020700 Selector valve grommet
10020900 Back up ring for grommet

9

10075980 Valve parts kit

a. diaphragm, b. armature,
c. spring, d. valve bonnet

10

10079010 Spring

11

10079000 Magnet

12

10035310 Siphon breaker

13

270702

Washer

14 a 440215

4 LPM Eductor assembly

b 441210

16 LPM Eductor assembly

c 3401-R

Eductor hose barb only

15 a 6422-A

4 LPM outer discharge tube

b 10074815 16 LPM outer discharge tube

Description

Part No.

Key

No Tip

.187

(3/16)

2:1

3:1

Grey

.128

(30)

2:1

3:1

Black

.098

(40)

2:1

4:1

Beige

.070

(50)

3:1

8:1

Red

.052

(55)

4:1

14:1

White

.043

(57)

5:1

20:1

Blue

.040

(60)

6:1

24:1

Tan

.035

(65)

8:1

30:1

Green

.028

(70)

12:1

45:1

Orange

.025

(72)

16:1

56:1

Brown

.023

(74)

18:1

64:1

Yellow

.020

(76)

24:1

90:1

Aqua

.018

(77)

32:1

128:1

Purple

.014

(79)

45:1

180:1

Pink

.010

(87)

128:1

350:1

Ratio (per Eductor Flow)

16 LPM

Tip Color

APPROXIMATE DILUTIONS

AT 2.86 BAR FOR WATER-THIN PRODUCTS (1.0 CP)

Orifice

Std. Drill

Size

Number

4 LPM

Содержание AccuDose 3876GB-2

Страница 1: ...VE STRAINERSPERIODICALLYFORCLOGGING CLEANIFNECESSARY 6 A short discharge tube is used with the 4 LPM eductor selector valve minimum tube length is 20 cm for correct operation A longer tube 1 2m is used with the 16 LPM eductor Slide end of tube with flooding ring over eductor discharge outlet The hose hook supplied may be installed on the long tube to allow it to conveniently hang from dispenser wh...

Страница 2: ... concentrate X 1 If the test does not yield the desired ratio choose a different tip and repeat the test Alternative methods to this test are 1 pH using litmus paper and 2 titration Contact your concentrate supplier for further information on these alternative methods and the materials required to perform them AccuDose Parts Diagram 5 7 8 4 2 3 1 6 1 238100 Strainer washer 2 10082835 Swivel collar...

Страница 3: ...are for 16 LPM discharge tubes 17 10061100 Support 18 10080920 Selector valve replacement kit e Suction stub f O ring g selector valve assembly 19 690014 Metering tip kit 20 500870 Tubing 6mm x 2 1 m 21 509900 Weight 22 10076301 Foot valve Viton EPDM also available Order 10076302 NOT SHOWN 641750 Security screws for cabinet sides Description Part No Key 9 10 11 12 13 14a 18 19 17 19 e 15a 22 21 20...

Страница 4: ...water running required to operate unit properly d Discharge tube s not in place d Push tube firmly onto eductor discharge or flooding ring missing from hose barb be sure inner discharge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged...

Отзывы: