7
4.3
Cautions
4.3.1
Do not operate in temperatures below freezing (0°C/32°F).
4.3.2
Before use, check for oil leakage. If there has been any leakage,
fix the leak and fill the pump oil.
4.3.3
Only use a power source with the electrical voltage (V),
frequency (Hz), and current (A) rating according to the machine
specifications.
4.3.4
Do not increase the operating pressure to over 1000 psi.
4.3.5
Do NOT use an extension cable than 30 ft. All extension cables
must be rated for the required voltage and amperage, and be
outdoor rated with a grounding prong.
4.3.6
The water supply pressure should be at least 30 psi for
continuous operation.
4.3.7
Water inlet temperature must not exceed 50°C/120°F.
4.3.8
Before use check that all hose fittings and high-pressure fittings
are FIRMLY attached and fully seated.
4.3.9
If a lower number of nozzles than recommended is used, the
system will be over-pressurized and the pump seals will
deteriorate quickly.
4.3.10
A valve installed at the end of a misting system is recommended.
It will help to easily purge air from the system, especially in
extensively long installations, or with configurations where air is
easily trapped in the misting lines.
4.3.11
When misting, check all nozzles and ensure none are blocked. If
blocked, clean or change the nozzle.
4.3.12
For storage during winter months, or where the pump will not be
used for an extended period of time, discharge the system
pressure and drain any standing water from the misting system
and filter housing.