1.
Please refer to ABL General Warnings Form no. 503.204 and 503.203.
2.
Be sure the power is off at the supply source.
3.
Ensure customer supplied 2-7/8” OD tenon
(B)
is properly installed and is capable of supporting fixture weight
and windload.
4.
Mount fixture
(A)
by sliding down over 2-7/8” OD tenon
(B)
and securing in place using the (4) four SS 3/8-16
fasteners
(C)
. Tenon angle should not exceed 45° from vertical.
5.
Route fixture cord through cord seal
(D)
and attach to backside of fixture yoke
(A)
. Tighten cord seal
(D)
outer
nut. Remove fixture yoke splice cover
(E)
and make all wiring connections to the fixture within the splice
compartment.
Note:
Make sure that there is enough cord left free for aiming of the fixture.
6.
Loosen (2) fasteners
(F)
on Yoke Locks and aim the fixture as required. Re-tighten the (2) screws
(F)
securely and the fixture is locked in position.
TPS3 MOUNTING ACCESSORY
TPS Series Yoke Mount Fixture
2-7/8” OD Tenon
(by others)
SS 3/8-16 Fastener
1/2” NPT Cord Seal Fastener Assembly
Yoke Splice Cover
SS 1/2-13 Yoke Fasteners
A
B
C
D
E
©2014 Acuity Brands Lighting, Inc.
3/13/14
INS-TPS3
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION
WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a
reference dimension: “Used for information purposes only. It does not
govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B
Chatsworth, CA 91311
Phone: 866.533.9901
Fax: 866.533.5291
www.hydrel.com
TPS3 SERIES
YOKE MOUNT
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
INSTALLATION INSTRUCTIONS
ATTENTION: DISCONNECT POWER BEFORE SERVICING
WARNING
- TO REDUCE RISK OF FIRE, USE APPROPRIATE LAMP
Lamp information is found inside luminaire. Removing the reflector may be necessary to view lamp information.
SUITABLE FOR WET LOCATION
MINIMUM 90°C SUPPLY CONDUCTORS
LES FILS D’ALIMENTATION DOIVENT CONVENIR POUR 90°C
p
!
F
B
A
E
C
F
D