Operating Instructions
-
4-6
Steamatic 8800 TMU
SHut doWn proCedure
flush clean water through the chemical system for 10 seconds. Turn the “CHeMICAl
1.
SeleCTIoN VAlVe” to “off.”
Cool the truckmount down by turning the “PUMP ClUTCH” switch to “PUMP oN
2.
- No HeAT”. Spray the cleaning wand into the vacuum hose for 3-5 minutes. The
chemical should now be flushed from the truckmount, hoses and cleaning tool.
Remove the vacuum hose.
3.
lubricate the blower to prevent it from rusting internally.
4.
Allow the unit to run for a few minutes with the vacuum hose disconnected in
a.
order to remove moisture from the blower.
Cap off the inlet(s) to the vacuum tank.
b.
Spray a HydraMaster-recommended spray lubricant into the “bloWeR lUbe
c.
PoRT” for about 5 to 10 seconds while the unit is running.
Uncap the inlet(s) and run the unit for another minute to allow the blower to cool
d.
down.
If freeze guarding is necessary, perform the procedure at this time. See the freeze
5.
Guarding section of this owner’s Manual (see page 5-19).
Press the engine throttle switch to the “IDle” position.
6.
Turn the ignition switch to “off.”
7.
Drain the water box using the valve.
8.
Drain the vacuum tank in an appropriate location.
9.
In accordance with ePA, state and local laws, do not dispose of water into gutters,
storm drains, streams, or reservoirs.
Perform daily maintenance as specified in Section
10.
5 of this owner’s Manual.
Содержание Steamatic 8800 TMU
Страница 2: ......
Страница 75: ...6 7 Water and Chemical System Steamatic 8800 TMU Chemical Flow Diagram Larger View Figure 6 5 7459...
Страница 76: ...Water and Chemical System 6 8 Steamatic 8800 TMU Figure 6 6 Exhaust Flow Diagram 7459...
Страница 78: ...Electrical System 7 2 Steamatic 8800 TMU Figure 7 1 Electrical Schematic 7458 Rev B...
Страница 82: ...Electrical System 7 6 Steamatic 8800 TMU...
Страница 126: ...Assemblies and Parts Lists 9 34 Steamatic 8800 TMU Blower Heat Exchanger Assembly Figure 9 24 7442...
Страница 146: ...How to Order Parts 10 2 Steamatic 8800 TMU...