Errors and troubleshooting
OFX
en(us)
Page 42 / 52
BeWa OFX 3796731 en-us 2014-03-31.doc
2014-03-31
Errors and troubleshooting
Error
Cause(s)
Remedy
The is no power at
the electric motor.
The power outlet used is free of
voltage.
The mains connector is not
plugged in. Plug in the power
plug.
Inspect the unit supply line for
damage. If the unit supply line is
defective, replace it immediately.
The mains voltage
or frequency do not
correspond to the
specifications on
the unit.
Use a unit that is suitable for the
mains voltage.
The unit is switched
off at the operating
switch.
Turn the unit on at the operating
switch.
Electric motor /
pump is not running
The thermal
overload protection
was triggered.
Reset the thermal overload
protection. For details refer to
page 44 in Section "Resetting
overload protection".
The hose coupling
is leaking
Retighten the screw connection
on the hose coupling.
The suction strainer
is clogged
Check or clean the suction
strainer.
The suction hose is
kinked or faulty or a
shut-off device is
closed
Check the suction hose for flow.
Replace it if necessary.
There is air in the
suction line and the
pump
Fill the pump via the suction
hose / hose coupling.
No oil flow
The viscosity of the
fluid is too high
Check the viscosity of the
medium.
Heat the medium to reach the
permissible viscosity.