8.
Remove the suction hose from the oil tank/container and
empty the contents back into the oil tank/container. Wind
the hose onto the hose retainer and insert the lance into
the holder.
9.
Secure the cable and, if required, the hoses to the filter
unit, see Transportation/storage.
O
The filter unit is ready for the next application.
Filtration up to the required cleanliness class:
Fig. 17:
Filtration to the cleanliness class operating mode
For filtration up to the required cleanliness class, proceed as
follows.
ü
Use the respective filter element with the required filtra-
tion rating.
ü
The setting of the limit value of the target cleanliness in
the ContaminationSensor has no effect on the operation
of the filter unit. An automatic switch off of the filter unit
after the limit value of the target cleanliness has been
reached, is not active.