Maintenance and Servicing Manual
FAM 200 FluidAqua Mobil
•
Open the shut-off fitting on the return side of the tank.
•
Start up the FAM again.
•
Switch off the FAM-200 after ca. 3 minutes.
•
Check the suction filter for leaking.
5.9
Changing the Filter Elementsof the Fine filter (10)
5.9.1 Before Removing the Filter Elements
•
Switch off the unit at the
key.
•
Close the ball valve at the inlet of the unit (1).
•
Close the shut-off fitting on the return side of the tank.
5.9.2 Removing the Filter Elements
Relieve the pressure to the filter housing. Carefully open the air-
vent plug in the cover using a size 10 mm Allen wrench.
The plug contains an air-vent slit — don't unscrew it
completely.
Open the drainage valve on the dirt side and capture any exiting
fluid (make sure to adhere to occupational safety and
environmental protection rules and regulations).
Close the drainage valve when fluid ceases to exit.
Undo the quick-action fastener between the cover and top-most
mid section using a size 13 open-ended wrench.
Remove the cover and set it on a clean surface.
Undo all star knobs
[A]
and remove the element retaining plate
[B]
.
[A]
[B]
Remove all the filter elements and dispose of them properly.
HYDAC Filtertechnik GmbH
en
Page 24
IuW FAM200 3373093a en.doc
2007-09-25