Maintenance and Servicing Manual
FAM 200 FluidAqua Mobil
Steps:
Remove the blue paneling.
Remove the guard.
Blow compressed air through the fins of the water
cooler.
Reassemble components in reverse order.
5.6
Flushing and Cleaning the Vacuum Pump (21)
You need:
•
Compressed air
•
VacuCleaner (for stock no. see
Replacement Parts List
)
FAM 200
: 4 liters
•
Measuring receptacle (5 liters)
•
Funnel
•
Hot water, ideally 60-65°C
FAM 200
: ca. 80 liters
•
Philips head screwdrivers PH#2 + PH#3
•
Slotted screwdriver, 0,6x4,5x100
•
Face pin spanner wrench 3-11-60 (for stock no. see
Replacement Parts List
)
Steps:
Drain the vacuum pump via the manual drain line.
Remove the blue paneling.
HYDAC Filtertechnik GmbH
en
Page 19
IuW FAM200 3373093a en.doc
2007-09-25