FAM 15/30/50/70
Troubleshooting
HYDAC Filter Systems GmbH
en
Page
51 /
68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc
2008-10-06
Change fluid filter
Step
Description
Malfunction:
"Replace fluid filter"
1.
Press RESET key
2.
Switch off the FAM at the main switch
3.
Close ball faucets on the IN and OUT connections
4.
Empty filter housing via the drain ball valve
5.
Open filter housing, remove filter elements from housing
6.
Insert new filter elements, close filter housing
7.
Open ball faucets on the IN and OUT connections
8.
Switch the FAM on with the main switch
9
Does malfunction reappear after
≈
4 minutes?
->a. Yes
-> proceed to Step 11.
10.
->b. No
-> proceed to Step 12.
11.
Check differential pressure switch and supply lines
12.
The failure is repaired.
You can find details on changing the filter element in the maintenance and service
instructions, document no. 3168098.