Performing maintenance / inspection
FAM 15/30/50/70 ATEX
en(us)
Page 63 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
Overview of maintenance intervals
See page
Daily or
24 hours.
Weekly or
100 hours.
Monthly or
500 hours.
E
ver
y
si
x
months
or
2000
hour
s
Yearly or
4000 hour
s.
FAM
Visual check for leaks
-
X
Check to ensure the screwed
fittings are securely tightened and
retighten if necessary
-
X
Check the measurement
technology equipment /
Underpressure manometer /
Dynamic pressure manometer at
the fluid filter
-
X
Check fault indicator lamps
X
Change the air filter
(if this has not been required
earlier)
X
Clean the suction strainer.
X
Lubricate the electrical cabinet lock.
X
Rotary Valve Pump Vacuum
Pump
Check oil level
X
Check oil for discoloration.
(See operating instructions of
vacuum pump)
-
X
Check that the oil filler neck and
drain plug have been properly
secured.
-
X
Check the vacuum pump for leaks.
X
Check the intake air filter and
replace if necessary
(See operating instructions of
vacuum pump)
X