Preparing the unit for operation
Filtromat – OF5 C with FCU
en(us)
Page 21 / 44
BeWa OF5C 3160333b en-us 2014-07-28.doc
2014-07-28
Hanging/connecting the pressure hose
Pull the pressure hose (thin hose) with lance out of the mounting in the floor
plate.
Using the lance, put the pressure hose with the lance into the appropriate
reservoir without straining or twisting it, and secure the suction hose to
prevent it from falling out or floating.
To prevent air from entering the medium, make sure that the pressure
hose with lance is always below the oil level in operation.
Electrical connection of the unit
Check or compare the local mains voltage and frequency specifications with
the specifications on the type label of the unit.
Plug the power plug of the OF5 into a suitable power outlet.
The unit has a motor protection switch in the on/off switch. If the nominal
current is exceeded, the motor protection switch trips.
Checking the direction of rotation
Check the direction of rotation of the motor by switching it on briefly (jog
mode). An arrow on the fan cover shows the correct direction of rotation for
the unit.
If the direction of rotation is opposite to the direction of the arrow, correct it
using the phase inverter contained in the connection plug, as shown in the
diagram below.
Содержание Filtromat OF5 C with FCU