background image

Appendix 

CSI-Connect 

Edition 2021-14-10 - V01 R08 

21

 / 

23

 

Part No.: 4576597 

 

 

 

For optimum system integration of HYDAC Condition Sensor Interface CSI-Connect, the following 
original accessories are available: 

 

The following connection cables for the sensors are available: 

Connector, female 

 

Connector, Male 

Length 

 

Part No. 

 

 

 

 

 

0.5 m 

ZBE 30-005 

4193586 

 

 

 

 

 

2 m 

ZBE 30-02 

6040851 

 

 

 

 

 

3 m 

ZBE 30-03 

6053924 

 

 

 

 

 

5 m 

ZBE 30-05 

6040852 

 

 

 

 

 + 

shielding 

10 m 

ZBE 30S-10 

3729098 

Table 16

: Connection cable Connector, female ↔ Connector, male

Connector, Female 

 

Cable with open end 

Length 

 

Part No. 

 

 

 

  + shielding 

5 m 

ZBE 42S-05 

3281239 

 

 

 

 + shielding 

10 m 

ZBE 42S-10 

3449681 

 

 

 

 + shielding 

5 m 

ZBE 47S-05 

3527626 

 

 

 

 + shielding 

10 m 

ZBE 47S-10 

3527627 

 

 

 

 + shielding 

2 m 

ZBE 08S-02 

6019455 

 

 

 

 + shielding 

5 m  

ZBE 08S-05 

6019456 

 

 

 

 + shielding 

10 m 

ZBE 08S-10 

6023102 

 

 

 

  

2 m 

ZBE 0P-02 

6052697 

 

 

 

 

2 m 

ZBE 08-02 

6006792 

 

 

 

  

5 m 

ZBE 08-05 

6006791 

 

 

 

  

5 m 

ZBE 47-05 

3484562 

 

 

 

  

10 m 

ZBE 47-10 

3484564 

Table 17

: Connection cable Connector, female ↔ Cable with open end

 

 

Содержание CSI-Connect

Страница 1: ...CSI Connect Sensor To Cloud Device for seamless cloud integration of industrial sensors Operating Instructions ...

Страница 2: ... Denmark Phone 45 93 63 64 55 E mail casper ladeby hydac dk Table 2 Documentation Representative Before you use this product for the first time or if you have been asked to carry out other work on the product please read this manual The use and the handling of the product described in the following are not self explanatory and are described in detail in this manual and the associated technical doc...

Страница 3: ...y are also able to recognize potential dangers Life phase Person Required knowledge Transport Storage Auxiliary Personnel No specialist knowledge required Electrical installation commissioning troubleshooting decommissioning Specialist electrician Safe handling use of tools Fitting and connection of electrical lines Knowledge of network communication Knowledge of using Windows PCs and of program i...

Страница 4: ...mple for procedural instructions with a fixed sequence 1 Remove the transport securing device 2 Fill the product 3 Switch the product on Procedural instructions that have a random sequence are listed as bullet points An example of a procedural instruction with a random sequence Clean the display Rinse the product In the case of some activities it is necessary to carry out work steps with intermedi...

Страница 5: ...ill find the following signal words DANGER The signal word indicates a hazardous situation with a high level of risk which if not avoided will result lethal or serious injury WARNING The signal word indicates a hazardous situation with a medium level of risk which if not avoided can result lethal or serious injury CAUTION The signal word indicates a hazardous situation with a low level of risk whi...

Страница 6: ...s which indicate particular hazards to persons property or the environment Signs used for giving orders These symbols are listed for all safety information and instructions in these operating instructions which indicate particular hazards to persons property or the environment Sign used for the required specialist personnel These symbols show the required training knowledge for installation work a...

Страница 7: ... and gross negligence Moreover it does not apply to defects which have been deceitfully concealed or whose absence has been guaranteed nor in cases of culpable harm to life physical injury and damage to health If we negligently breach any material contractual obligation our liability shall be limited to foreseeable damage Claims due to the Product Liability shall remain unaffected All rights to th...

Страница 8: ...nect only with Permitted HYDAC SMART sensors or the permitted analogue sensors Ensure correct pin wiring of the connected analogue sensors Connection of more than 4 permitted analogue sensors Erroneous or no communication Connect a maximum of 4 permitted analogue sensors to the CSI Connect Exceeding the maximum permissible line length Erroneous or no communication Observe the maximum permissible l...

Страница 9: ...ors via 4 M12x1 connectors Easy system integration due to industrial network connectors M12x1 Wireless transmission of the measured values via LTE with 2g 3g fallback Parameterization of the product i e sensors RESTapi via cloud Integrated mounting brackets for wall fastening or directly on the system accessory Due to a high protection class of IP 65 no switch cabinet for installation required The...

Страница 10: ...y combination of the two totalling a maximum of four connected sensors at any time The device is compatible with the following sensors Permitted HYDAC SMART sensors Analog output only CS1000 Series HYDACLab HLB1000 series Permitted analogue sensors with analogue output 4 20mA load 500Ω 0 20mA load 500Ω 0 10V DC 0 5V DC 2 10V DC 1 5V DC Example Temperature measurement transformer pressure measureme...

Страница 11: ...rating temperature range 20 65 C Storage temperature range 30 80 C Relative humidity 0 70 non condensing marked EN 61000 6 2 EN 6100 6 4 Protection class according to DIN 40050 IP 65 Table 8 Ambient conditions Supply voltage 12 24 V DC 10 Current requirement module 100 mA with 1A bursts plus connected sensors Sensor supply 12 24 V DC looped through Electrical connection Supply voltage Connector M1...

Страница 12: ...uction hardware index Table 10 Decoding the model code label The CSI Connect has the following model code CSI C 12 0 0 1 0 000 Product Series CSI ConditionSensor Interface Housing C Metal housing compact Signal output 1 Wireless wide area communication 12 Integrated cellular communication 2G 3G 4G LTE CAT M1 Signal output 2 wireless near field communication 0 Without 1 Bluetooth Signal output 3 ha...

Страница 13: ... possible Only remove the packaging just before installing the unit Observe the storage conditions given in Chapter Technical Data 11 This chapter provides information on assembly installation and commissioning The CSI Connect is delivered pre assembled Before operation 1 Connect the antenna 2 Connect the desired sensors to the CSI Connect analogue sensor channels 1 to 4 3 Connect the device to po...

Страница 14: ...onnect Supply voltage GND 1 4 Not allocated 1 5 Not allocated 2 5 1 12 24 V DC Analogue sensor 1 4 Supply voltage UB 2 5 2 Not allocated 2 5 3 Signal Analogue sensor 1 4 Analogue signal input 2 5 4 GND Analogue sensor 1 4 GND supply vultage 2 5 5 Not allocated Table 11 Plug Pin assignment Here you will find a connection example for the CSI Connect Figure 3 Connection example CSI Connect CS1000 HDA...

Страница 15: ...say Signed in 3 Click Find Device Online in the overview tab A dialog window will appear showing all CSI Connect devices that are online and claimed to the account o If setting up a new CSI Connect click Add device and enter the serial number of the CSI Connect in question click OK o Choose the desired CSI Connect from the list by clicking it then click OK The dialog will close and the name and ID...

Страница 16: ...uld be pushed to Click Create New Data will now be pushed to CMX For all other integrations click either the Custom Web Hook or the Advanced tab In the Custom Web Hook tab Enter the URL of the endpoint to hit Choose the Request type from POST PUT DELETE and GET Most common is POST and PUT Choose whether the data should be in a JSON or plain text The difference is that if JSON is chosen it is not p...

Страница 17: ...Range Maximum value of the analogue channel connected sensor Data Stream Data Stream settings Sample Period The amount of time between data events in seconds Mode Can be selected between Off Continuous Threshold Threshold Channel Can be chosen from Analog 1 to Analog 4 If Data Stream Mode is set to Threshold data events will only be sent if the value of the chosen Threshold channel lies between Lo...

Страница 18: ... Settings Sample Period 10 Mode Off Threshold Channel Off Lower Threshold 0 Upper Threshold 100 Table 13 Factory settings for the CSI Connect For operation switch on the voltage supply to the CSI Connect or plug a power supply unit into a suitable socket During operation note the cloud and status LEDs on the CSI Connect For descriptions of the different colours of the two LEDs please refer to Tabl...

Страница 19: ...r cable Green Blinking Looking for cellular signal Normal step in the start up process it might take a couple of minutes but if the CSI connect stays like this for too long consider checking that the antenna is mounted correct and try repositioning the device as the placement may mean it cannot get a signal Cyan Blinking Connecting to the cloud servers Normal step in the start up process and will ...

Страница 20: ...including all its components before decommissioning Disconnect or remove the electrical connection Dispose of the packaging material in an environmentally friendly manner After dismantling the product and separating its various materials into categories dispose of all parts in an environmentally friendly manner ...

Страница 21: ...4 5 m ZBE 30 05 6040852 shielding 10 m ZBE 30S 10 3729098 Table 16 Connection cable Connector female Connector male Connector Female Cable with open end Length Part No shielding 5 m ZBE 42S 05 3281239 shielding 10 m ZBE 42S 10 3449681 shielding 5 m ZBE 47S 05 3527626 shielding 10 m ZBE 47S 10 3527627 shielding 2 m ZBE 08S 02 6019455 shielding 5 m ZBE 08S 05 6019456 shielding 10 m ZBE 08S 10 602310...

Страница 22: ... available Part No Female connector with screw terminal 5 pole M12x1 to DIN VDE 0627 6049128 Female connector with screw terminal with shielding 5 pole M12x1 to DIN VDE 0627 ZBE 08 6006786 Female connector with screw terminal 8 pole M12x1 to DIN VDE 0627 ZBE 44 3281243 Female connector with screw terminal 8 pole M12x1 to DIN VDE 0627 ZBE 0P 6055444 Table 18 Connectors female ...

Страница 23: ...mation 8 3 Product overview 9 3 1 Scope of delivery 9 3 2 Dimensions 9 3 3 Proper Designated Use 10 3 4 Improper Use or Use Deviating from Intended Use 10 3 5 Technical Data 11 3 6 Decoding the model code label 12 3 7 Model code 12 4 Storage and transport 13 5 Assembly installation and commissioning 13 5 1 Assembling the CSI Connect 13 5 2 Connection overview 13 5 3 Commissioning 15 6 Factory sett...

Отзывы: