HYDAC FILTER SYSTEMS GMBH
Rectifying malfunctions | 7
MoWa OLFCM 3573893a en-us lq
51 / 80
Malfunction
Cause(s)
Rectification
the circulation of
the fluid within
the pump (pres-
sure relief valve
opened) and
normal pump op-
eration has then
started.
Leakage at the
filter bowl/filter
cartridge
The drain plug at
the filter housing
or the housing
clamps at the fil-
ter bowl are
loose.
Tighten the nuts
of the housing
clamps to the re-
quired torque.
In the case of a
Spin-On filter
cartridge, tighten
it fully. If neces-
sary, replace the
filter cartridge
seal.
Tab. 10:
Error/cause/rectification
Malfunction
Cause(s)
Rectification
The running
noise of the mo-
tor-pump assem-
bly becomes
substantially
louder.
The protective
screen is
clogged.
Clean the pro-
tective screen.
The pump is not
sucking or suck-
ing badly.
There is no oil in
the pump.
Fill the pump via
the suction hose.
Содержание OLFCM 10/15