5 | Mounting/installing
HYDAC FILTER SYSTEMS GMBH
44 / 80
MoWa OLFCM 3573893a en-us lq
5.6 Connecting the pressure port (OUT)
Use a connector that is suitable for the port. The size of the
connection and the type of the threads can be found in the
"Technical data" chapter
NOTICE
Pressure port/outlet OUT closed
The filter unit/filter housing will be damaged/destroyed
u
Make sure that the pressure port is always open during
operation.
5.7 Electrically connecting the electric motor
Check the connection voltage as well as the frequency of the
electric motor and balance it with the available mains supply.
You will find the electric data on the name plate of the electric
motor. Install a motor protection switch matched to the nominal
current of the electric motor.
DANGER
Dangerous electrical voltage warning
Danger of fatal injury
u
All electrical jobs must be carried out by specialists with
the respective knowledge for the job.
u
Pull the power plug and ensure the unit is deenergized.