HYDAC FILTER SYSTEMS GMBH
Setting up / assembly / integration of the filter unit | 6
BeWa MFU-10P 4391553b en-us
51 / 124
6.2 Avoiding siphoning
If there is a height difference
ΔH
between the suction side and
pressure side container side / system, the low lying line can
develop a suction effect and trigger the siphoning effect be-
tween the communicating containers / systems. This siphoning
effect also occurs when fluid is pumped in a pre-pressurized
reservoir.
Fig. 19:
Avoiding siphoning
NOTICE
Siphoning effect
Reservoir overflowing/leaking = oil spill
u
Remove the ends of the hoses from the reservoir after op-
eration or shut the shut-off device in the suction line.