5 | Setting up/assembling/commissioning
HYDAC FILTER SYSTEMS GMBH
32 / 64
BeWa CTM-EF3x3x 4436386 en-us lq
5.2 Electrical connection
ü
The extraction unit is supplied ready for connection with a power plug fit-
ted.
1. Before plugging in the power plug, please compare that the voltage from
the available network corresponds to that specified on the name plate of
the extraction unit.
2. Plug the power plug only into a power outlet with a ground connection.
O
The extraction unit is electrically connected to the supply network.
5.3 Connecting the compressed air supply
The extraction unit requires a compressed air connection for operation. The
compressed air requirements can be found in Chapter
1. Connect the quick-action coupling of the compressed air supply to the
standard connection nipple of the low-pressure series DN 7.2 on the ex-
traction unit.
2. Open the shut-off valves that may be present in the supply line.
3. Check the state and the setting of the maintenance unit in the supply line.
O
The pressure port is connected.
5.4 Connecting the CTM-EF extraction unit to
the GTM-SC supply module
So that both modules work together, the electrical as well as the hydraulic con-
nection is required.
Screw wrench
= 22 mm
Attach the male connector to the control unit and also attach the connection
hoses of the CTM-EF3xxx to the CTM-SC as shown in the following illustration.