background image

 

 
 

From serial  
No. 5688  
 
 
 

 
 
 

 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

Prior to Operation 

 

We thank you for choosing a 
HYCON powerpack. 
 
Please note that the power-
pack is delivered without hy-
draulic oil, and therefore it 
must be filled up with hydrau-
lic oil prior to operation. 

 

To ensure smooth operation 
and long-lasting performance 
of your new powerpack, we 
recommend you to study this 
operating manual carefully and 
pay special attention to the  

 

Safety and Service 
Precautions

  

 

We hope you will be satisfied 
with your new HYCON power-
pack. 
 
Best regards 
HYCON A/S 

 

 

HYCON A/S 

Juelstrupparken 11 
DK-9530 Støvring 
Danmark 
 
Tel: +45 9647 5200 
Fax: +45 9647 5201 
Mail 

[email protected]

 

www.hycon.dk 

 

HPP06 
Hydraulic Powerpack 

Содержание HPP06

Страница 1: ...ensure smooth operation and long lasting performance of your new powerpack we recommend you to study this operating manual carefully and pay special attention to the Safety and Service Precautions We...

Страница 2: ...cautions 2 Filling up hydraulic oil 2 Technical data 3 Starting instructions 4 Service maintenance and hydraulic settings 4 Fault location 5 Oil types 7 EC Declaration of Conformity 8 Warranty conditi...

Страница 3: ...from a vehicle we recommend the use of a crane 8 The pressure relief valve is set at 110 bar from our plant Never set it higher 9 Always use filters with by pass The use of filters without by pass may...

Страница 4: ...110 bar Pump Gear pump Oil temperature Max 70 C Hydraulic oil tank capacity Min 5 litres max 7 litres Petrol tank capacity 3 1 litres Hydraulic system compl Max 8 litres Filter system filter element...

Страница 5: ...witch to 1 Pull recoil starter Move the lever to ON Stop Move the lever to OFF Turn off the ignition switch Turn the fuel tap to OFF Service Maintenance and Hydraulic Settings Service Maintenance Dail...

Страница 6: ...etighten the lock nut after adjustment 2 When the pressure relief valve has been adjusted correctly the working pressure must be set at 100 bar by means of the valve on the test equipment At 100 bar t...

Страница 7: ...lutions must not exceed 3300 r p m at 18 l p m If the number is higher there may be dirt in the pressure relief valve or the pump may be worn Problem Cause Solution Powerpack does not give the right o...

Страница 8: ...ses standard hydraulic oil i e all types of mineral oil and biodegradable oil which comply with the following values Recommended viscosity 20 40 cSt Permitted viscosity 15 1000 cSt Viscosity index Min...

Страница 9: ...irectives 2006 42 EC and 2000 14 EC Notified Body 1585 AkustikNet A S Frederikssundsvej 179 B DK 2700 Br nsh j Denmark Guaranteed sound power level 100 dB HYCON A S Juelstrupparken 11 DK 9530 St vring...

Страница 10: ...plies to faults that can be related to construction and production errors Faults caused by incorrect operation incorrect handling lack of maintenance or the like will not be accepted as warranty The w...