Product Instruction Manual 

Vicenza

 

No Glare Infrared Radiant Heater

VC1200T, VC2400T

V19.10,1

Содержание Vicenza VC1200T

Страница 1: ...Product Instruction Manual Vicenza No Glare Infrared Radiant Heater VC1200T VC2400T V19 10 1...

Страница 2: ...ead these instructions before commencing installation and follow to ensure that installation and operation are simple and safe Do not use the heater if the power cord is damaged The heater must not be...

Страница 3: ...shall not plug in regulate or clean the heater or perform user maintenance Keep the power cable from touching the heater body as the heater will get very hot CAUTION Some parts of this heater can beco...

Страница 4: ...diagram 1 The heater must be installed a minimum of 1800 mm from the floor There are two types of horseshoe bracket H which are to be attached to the heater have threaded screw holes and W to be attac...

Страница 5: ...acing inwards the distance between the screw holes will be approximately 660 mm from the first bracket for the 1 2 kW model and 1260 mm for the 2 4 kW model Note tabs on wall face outwards and tabs on...

Страница 6: ...ng 85 mm apart from each other Using the fixings provided attach one of the W horseshoe brackets to the ceiling ensuring the tabs are facing outwards The bracket can be used as a template if required...

Страница 7: ...most appropriate angle Ensure the brackets on the ceiling and the unit overlap so that the wing nut bolts will fit through and secure both together using the wing nuts with the wing nut bolt going in...

Страница 8: ...r setting indicator Use up and down buttons to select the desired maximum room temperature setting This will automatically save after 5 seconds and return to operational mode Once the temperature has...

Страница 9: ...r is in locked mode In order to unlock press the lock button followed by the standby button again and the LOCK indicator will disappear from the LED screen Display Screen On Off The display button giv...

Страница 10: ...W Auxiliary electricity consumption At nominal heat output elmax 1 130 2 283 kW At minimum heat output elmin 0 581 1 125 kW In standby mode elSB 0 17 0 17 W 8 Information Requirements for Electrical L...

Страница 11: ...put and no room temperature control No No Two or more manual stages no room temperature control No No With mechanic thermostat room temperature control No No With electronic room temperature control N...

Страница 12: ...parts or replacement warranty for a period of 12 months from the date of purchase If there is a manufacturing defect within the warranty period we will send spare parts repair and return the unit or...