HYBRID POWER POWER TOWER 120V Скачать руководство пользователя страница 1

1

Batt Pack Energy - User manual - English

POWER TOWER

User

 Manual

+1 (647) 347-6000

www.hybridpd.ca

CONF

SELECT

SELECT

ENTER

Manufactured by:

hybridps.ca

288 

Judson St #5

ON M8Z 5T6

Содержание POWER TOWER 120V

Страница 1: ...1 Batt Pack Energy User manual English POWER TOWER User Manual 1 647 347 6000 www hybridpd ca CONF SELECT SELECT ENTER Manufactured by hybridps ca 288 Judson St 5 ON M8Z 5T6...

Страница 2: ...2 Batt Pack Energy User manual English...

Страница 3: ...ks when subjected to high temperatures 150 C 302 F when damaged or abused e g mechanical damage or electrical overcharge Burning cells can ignite other batteries in close proximity Vapors or mists fro...

Страница 4: ...4 Power Tower User manual English MANUAL INDEX...

Страница 5: ...CONTENT PAGE Overview 06 Safety Information 08 Installation 11 Grounding and solar wiring 16 System configuration 19 Specifications 28 Warranty 33 Disposal 36 Appendix 38...

Страница 6: ...6 Power Tower User manual English OVERVIEW SECTION 1...

Страница 7: ...l for future reference 1 2 Scope This document defines the functional requirements of the unit intended for worldwide use in electronic processing equipment All manuals are applicable under all operat...

Страница 8: ...SAFETY INFORMATION SECTION 2...

Страница 9: ...n working with metal tools on or around batteries The potential exists to drop a tool and short circuit the batteries or other electrical parts resulting in sparks that could cause an explosion Turn O...

Страница 10: ...trical parts resulting in damage injury or death REMOVE personal metal items such as rings bracelets necklaces and watches when working with the battery Battery can produce short circuit current high...

Страница 11: ...INSTALLATION SECTION 3...

Страница 12: ...tor Start connector and pins Qty 1 Set of keys 3 2 Basic Configuration The Power Tower is designed to serve as an off grid power supply for AC loads The input power for the Power Tower comes from eith...

Страница 13: ...s All cabling provided should not be cut or trimmed as this will create an imbalance in resistance throughout the cabling and cause performance issues Up to 5 batteries Five batteries can be connected...

Страница 14: ...es match the most common generator plug type 120 240V plugs A simple extension cord between both will enable quick installation Ensure all local electrical codes are met when wiring the input ALWAYS E...

Страница 15: ...Each plug has a 30A breaker to ensure no more than 30A is drawn per plug Ensure that the phases are matching Single 120V 30A Input When charging the Power Tower system using only a single 120V 30A inp...

Страница 16: ...GROUNDING SOLAR WIRING SECTION 4...

Страница 17: ...nd neutral wire should be bound and should be connected to the negative battery bus To do so connect the grounding point on the Power Tower to the negative terminal of the battery Connect the output n...

Страница 18: ...l solar or wind charger installation requirements Ensure that the total charging amperage does not exceed the maximum allowable charging amperage for the battery For example a system with three 3 Powe...

Страница 19: ...SYSTEM CONFIGURATION SECTION 5...

Страница 20: ...ad of depleting batteries This ensures that when the automatic generator starter turns on the generator power from the generator will be used to power both the output your home as well as charge the b...

Страница 21: ...ror Please contact HPS Led color GREEN Led color GREEN Led color YELLOW Led color RED ICON DEFINITION Power Tower Operating Normally Line Mode is enabled PV input is connected Backup Mode is enabled B...

Страница 22: ...Changing System Settings CHANGE SETTING AT YOUR OWN RISK CONTACT HPS FOR ASSISTANCE Any settings change may result in product damage fire shock injury and or death The below instructions should only b...

Страница 23: ...Voltage Setting 3 Output frequency setting 220 1 220 1 Narrow Range Mode 95V 131Vac Four Options 105Vac 110Vac 115Vac 120Vac 50Hz 60Hz Automatic 50 60Hz frequency output can be adjusted as well as th...

Страница 24: ...wer User manual English SETTING DESCRIPTION OPTIONS 4 AC Charge 5 AC Charger Current 6 AC DC Mode Selection AC Charge ON 20A 35A 50A AC Priority DC Priority AC Charge OFF 4 35A 4 35A 5 35A 6 6 6 Intel...

Страница 25: ...0V output model 5 3 3 Operating Indicators AC MODE AC PV MODE Voltage and Frequency change display every 5 seconds Voltage and Frequency change display every 5 seconds DC MODE PV MODE Voltage and Freq...

Страница 26: ...again 3 Output short circuit alarm light on Close the inverter and disconnect all load equipment inspect load equipment if any of them had fault or internal short circuit then start the inverter again...

Страница 27: ...than the inverter s rated power after reducing load equipment quantity the inverter will operate normally 8 Over charge alarm light on Battery type selection incorrect Charger damaged please consult...

Страница 28: ...SPECIFICATIONS SECTION 6...

Страница 29: ...INPUT FREQUENCY 50Hz 60Hz Auto detection 50Hz 60Hz Auto detection LOW LINE FREQUENCY DISCONNECT 40 0 3Hz for 50Hz 50 0 3Hz for 60Hz 40 0 3Hz for 50Hz 50 0 3Hz for 60Hz LOW LINE FREQUENCY RE CONNECT 4...

Страница 30: ...z 0 3Hz OUTPUT VOLTAGE REGULATION 10 10 NOMINAL EFFICIENCY 87 Normal DC Input 60 R load 87 Normal DC Input 60 R load OVERLOAD PROTECTION 105 load 150 beeps 0 5s every 1s and Fault after 60s Load 150 b...

Страница 31: ...85Vac 4 WID LOW LINE RECONNECT 98Vac 4 NOR 88Vac 4 WID 190Vac 4 NOR 150Vac 4 WID NOMINAL CHARGE CURRENT 10 20 30 40 50A 10 20 30 40 50A CHARGE CURRENT TOLERANCE 5A 5A OVER CHARGE PROTECTION Bat V 59 2...

Страница 32: ...the earth joined Line mode the neutral and the earth separated Use a Relay to realize the function AUDIBLE NOISE 60dB max no noise at low load low heat COOLING Forced air variable speed fan SIZE L W...

Страница 33: ...WARRANTY SECTION 7...

Страница 34: ...2 Owner s Warranty Responsibility If the product does not operate as warranted above during the applicable warranty period HPS shall at its option and expense except for shipping cost repair the defec...

Страница 35: ...nforceable provisions were replaced by valid legal and enforceable provisions that come closest to the intent underlying the invalid or unenforceable provision The united nations conventions on contra...

Страница 36: ...DISPOSAL SECTION 8...

Страница 37: ...he product to or contact HPS for safe recycling Disposal of the product at the end of its service life shall be done in accordance with applicable disposal regulations for electronic waste The product...

Страница 38: ...APPENDIX SECTION 9...

Страница 39: ...ed in series or parallel in order to obtain the desired output voltage and current which meets the inverter s allowed range When connecting PV panels in series the max voltage and current of the strin...

Страница 40: ...0W Solar Installed Pmax 260W Voc 37 7V Isc 8 89A Vmp 30 9V Imp 8 42A 1 The max PV input power for the Power Tower is 3500W 3500W 260W 13 46 min 10 PV panels shall be connected 13 2 Best Operating Volt...

Страница 41: ...41 Power Tower User manual English INVERTER Figure 8...

Страница 42: ...POWER TOWER...