HW Group HWg-SH4 Скачать руководство пользователя страница 1

HWg-SH4

User guide

Содержание HWg-SH4

Страница 1: ...HWg SH4 User guide...

Страница 2: ...wer supply outlet or a disconnection device has to be freely accessible The device must not be used under any of the following conditions The device is noticeably damaged The device does not work corr...

Страница 3: ...tem 11 Logic architecture of the system 12 Usage examples 13 Use of HWg SH4 in small applications 13 Use of HWg SH4 in IT environment 15 Thorough description of the WWW interface 18 General setup 18 E...

Страница 4: ...a centers technological rooms commercial spaces apartment houses and offices Out IN3 IN2 IN1 IN3 IN2 IN1 DCD Lock 2 Lock 1 Power Status Out GND U NO COM NC Ethernet Set RFID1 RFID2 Relay Power GND IN1...

Страница 5: ...ID tags RFID tags database can be managed through a built in web interface in offline mode Internal database allows its administrators to manage 2000 user RFID tags Online mode uses central management...

Страница 6: ...Lock1 Lock2 sockets for connecting door modules Each module consists of one switch relay max 50V 1A for a lock and three pairs of binary inputs with fixed functions door contact exit button lock cont...

Страница 7: ...ion to Ethernet network is working LINK LED will light up orange light on RJ45 connector and it then flashes during the data transmittions Activity signalisation Setting an IP address HWg Config HWg C...

Страница 8: ...the name Save the settings with Apply Changes button To set the IP address you can also use UDP Config for Linux WWW interface WWW interface of the device can be opened by one of the following steps O...

Страница 9: ...nt options Modules output control options and alarm settings SNMP SNMP SNMP traps settings ports and alarm messages recipients System FW upgrade configuration download options etc Door closed and unlo...

Страница 10: ...The access rights are afterwards copied to HWg SH4 devices Main advantage of this mode is its ability to manage large networks with many users HWg SH4 units and subordinated units HWg SH4e and HWg SH...

Страница 11: ...odules of their master HWg SH4 Adding HWg SH4x module into HWg SH4 system Units subordinated to HWg SH4e and HWg SH4s can be added through the WWW interface of HWg SH4 on Modules page by Add Module li...

Страница 12: ...connector Predefined objects Both RFID readers are connected independently and types of the readers can be combined You can then for example connect an EM4100 together with Mifare reader which would a...

Страница 13: ...nies or systems using existing RFID tags Apartment building access system HWg SH4 can be used as an access system for apartment houses or offices A typical application can be using RFID reader for acc...

Страница 14: ...at the gate can be then used for evidence of cars parked in the parking lot Using the HWg DCD is optional here as well Building access system with availability for other applications Thanks to the abi...

Страница 15: ...ID reader is placed on one of the doors or both If there is only a single HWg SH4 it can be simply configured in offline mode through its WWW interface However if HWg SH4 is installed in a data center...

Страница 16: ...ntrol the door locks are installed in individual rack cabinets NOTE The units both head and subordinated can also use relay type objects for example for lighting control in racks or for identification...

Страница 17: ...ined by a code entered on the keypad HWg SH4 as another access point In this configuration the HWg SH4 works as an access point it controls subordinate units and opens door as well The door is selecte...

Страница 18: ...depends on actual requirements of the user and the network administratior IP Address IP address of the HWg SH4 assigned by a network administrator Network Mask assigned by a network administrator Gate...

Страница 19: ...ters of alarm e mail messages starts or endings of alarm states Check this before sending an e mail 1 Correct Gateway IP address 2 DNS server in the network settings 3 SMTP server and its port 4 Activ...

Страница 20: ...tually for filtering and further processing of alalrm messages TO recipient e mail address of alarm e mails recipient Only one e mail address can be entered CC copy e mail address of alarm e mails cop...

Страница 21: ...re the HWg SH4 is located required for events logging Summertime allows DST switching required for correct logging of the measured values and events Interval interval of a time synchronisation with a...

Страница 22: ...y name of SNMP community for access to HWg SH4 over SNMP 2 communities can be defined and each can have rights assigned to Read Write SNMP Trap Destination section Destination index of a target destin...

Страница 23: ...onnect Disconnect only for network modules HWg SH4e and HWg SH4s Send SMS when RFID state changes allows sending of notification in case of a specific reader object event Available events RFID Tag inv...

Страница 24: ...out return into the normal state Send SMS when the door state changes allows sending of notification in case of a specific event Available events Open Close door opened or closed Lock Unlock door lock...

Страница 25: ...DCD Enable turns this function on off more in Functionality mode selection chapter Enable online mode Disable offline mode Server Address IP address of the HWg DCD server Server IP Port TCP port for H...

Страница 26: ...f accesses and a list of users with options of editing are displayed on this page in the offline mode RFID Card log section Shows log of the most recent events with options of adding and removing user...

Страница 27: ...ion an option for editing or deleting users Add User link Used for adding users Adding users Enter Name and Surname of the RFID tag user Please use the Card Id field to enter a unique ID of the RFID t...

Страница 28: ...stems Type type of the connected module Available options are HWg SH4e HWg SH4s and Hermes10 discontinued IP Adress IP address of the connected module If you enter an address of a device which was not...

Страница 29: ...HWg SH4 29 Objects configuration This page is used for thorough configuration of objecs as setting the locks types RFID readers etc Door type object Description of the WWW interface...

Страница 30: ...tem defined in the firmware this field is prepared for future use Model defines type of the connected accessories and therefore also types of the connected elements Description shows the elements conn...

Страница 31: ...stic information for troubleshooting Build diagnostic information for troubleshooting UpTime uptime since last power on or reset of the device Diagnostic information for troubleshooting Demo mode acti...

Страница 32: ...system Server application with extended logging capacity Access log and event log mirroring from HWg SH4 to HWg DCD Communication between the device and HWg DCD based on events or periodical checks H...

Страница 33: ...in order to make work with HWg DCD more fluent Connection between HWg SH4 and HWg DCD is caused by any action on the side of the HWg SH4 or randomly in 30 90s period Any changes done in HWg DCD will t...

Страница 34: ...objects doors readers relays Allows defining and grouping of components placed at the same locations Door objects connected to the same device can be placed in different groups also door and reader ob...

Страница 35: ...s service IP address In case the service is not running on the same device as user GUI behaviour of GUI for folders browsing and default display options Group Window Group window displays the trees o...

Страница 36: ...ems with the system More information can be found in Application note on the manufac turer s websites or on request from your local distributor Settings window Settings window shows an overview of set...

Страница 37: ...Card Number field can be filled in manually or after clicking the administrator RFID reader icon a card with admin rights can be read Erasing and editing accounts Users can be edited after clicking t...

Страница 38: ...mory POWER input Port POWER 12V DC Power input 12V DC 2 5W typically 250 mA Connectors Jack barrel inner 2 5 mm outer 6 3 mm Terminal Block POWER output Voltage Power Out Power IN Current Connector Ma...

Страница 39: ...stinguished by a LED light Isolation Switch contacts are galvanically isolated from the rest of the device Inputs DI inputs for binary contacts Inputs DI inputs for binary contacts Dry contacts or GND...

Страница 40: ...an optional accessory Connecting HWg R3 RFID reader RJ45 standard B colours Function HWg R3 JA 8H white orange 1 out 1 gray yellow orange 2 out 2 purple x x 3 Txd x x blue 4 GND black blue x 5 in 1 x...

Страница 41: ...nnector s body and press the parts firmly together Use the supplied strap to prevent the cable from being pulled out of the connector Cut off the spare part of the strap The metal body of the connecto...

Страница 42: ...nection rules for different elements Out1 Relay closed when unlocking In1 Door contact dry contact is closed when the door is closed In2 Not used In3 Exit Button closing the dry contact unlocks the do...

Страница 43: ...HWg SH4 43 Connecting HWg SH4 accessories Connecting E lock XPO 211 lock detail of connection...

Страница 44: ...o HWg SH1 detail of connection green white Power GND Power Out GND pin green Power 12V Power Out U pin x Not used orange Control Signal to Rele NO pin Rele COM connect to Power Out U pin blue white Lo...

Страница 45: ...e the factory default settings of the device also erases all passwords 1 Turn the device off by disconnecting the power supply 2 Swith the DIP1 ON 3 Turn the device on switch the power supply 4 Wait a...

Страница 46: ...Notes...

Страница 47: ......

Страница 48: ...HW group s r o Rumunsk 26 122 Praque 2 120 00 Czech republic Tel 420 222 511 918 Fax 420 222 513 833 www HW group com...

Отзывы: