8
1 of 8
R3HV-M/F
Technical Data Sheet
Rev A
Specialty Products
R3HV-M/F
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F)
24
Evaporator (F)
20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Front
Btu/hr/ft*
Parallel
650
Conventional 748
Top
Parallel
565
Conventional 650
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs
6
OFFTIME
Temp Term °F
54
Failsafe Minutes
40
ELECTRIC or GAS Not Recommended
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1 ½*
Merchandiser Liquid Line (in.)
3/8*
Merchandiser Suction Line (in.)
5/8*
Estimated Charge (lb)***
4ft 1.2
5ft 1.5
6ft 1.8
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
GLYCOL REQUIREMENTS
GPM PSI
NA
NA
NA
NA
NA
NA
CUL Listed
UL Sanitation
Содержание Specialty Products CR3HV-F
Страница 2: ...8 2 of 8 R3HV M F Technical Data Sheet Rev A Specialty Products R3HV M F Engineering CROSS SECTION ...
Страница 4: ...8 4 of 8 R3HV M F Technical Data Sheet Rev A Specialty Products R3HV M F ...
Страница 5: ...8 5 of 8 R3HV M F Technical Data Sheet Rev A Specialty Products R3HV M F ...
Страница 6: ...8 6 of 8 R3HV M F Technical Data Sheet Rev A Specialty Products R3HV M F ...
Страница 7: ...8 7 of 8 R3HV M F Technical Data Sheet Rev A Specialty Products R3HV M F ...
Страница 8: ...8 8 of 8 R3HV M F Technical Data Sheet Rev A Specialty Products R3HV M F ...