background image

M4 Data Sheet

6 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Standard Lighting  1 Row Canopy  or Optional 1 Row Rail

Light Circuits

Optional  Lighting  2 Rows Canopy

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

=  120V P

OWER

=  120V N

EUTRAL

Grayed components in 12 foot models only.

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

Optional  Lighting  3 Row Canopy

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

5

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

BL

R

R

BL

BL

4

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

5

5

5

W

B

BL

R

R

BL

BL

4

5

5

R

5

R

R

R

R

R

5

Содержание IMPACT M4

Страница 1: ...otor B 0411744 Standard Non adjustable 2 Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Note Changed items have been underlined Merchandisers D E E A E C D B M4 Data Sheet Set P N 0378419C NSF Certified December 2003 Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace wi...

Страница 2: ...between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Electrical Field Wiring connection point B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of c...

Страница 3: ...ration and product loading OFFTIME M4 M4E Temp Term F 48 F 48 F Failsafe Minutes 25 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure Backup Control M4 M4E CI CO 12 2 F 14 4 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser D...

Страница 4: ... 120V 60Hz 3 00 4 40 Export 230V 50Hz 1 72 2 48 With Energy Efficient Fans 120V 60Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1 Row ...

Страница 5: ...ector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All component...

Страница 6: ...models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch ...

Отзывы:

Похожие инструкции для IMPACT M4