background image

P/N 0378419C

3 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

1

/

2

(152)

44 

1

/

2

(1130)

38 

1

/

8

(969)

1

/

8

(79)

73 

7

/

8

(1877)

46 

3

/

4

(1187)

30 

1

/

8

765)

1

/

(165)

40 

3

/

4

(1035)

12 

5

/

8

(319)

4

 

(102)

27 

1

/

(699)

4

(102)

1

/

2

(114)

29 

1

/

(749)

35 

1

/

(891)

46 

1

/

(1174)

26 

1

/

4

(668)

FAN

C
O

I

L

M4

21 

1

/

2

(547)

13 

3

/

8

(339)

REFRIGERATION DATA

Note:

This data is based on store

temperature and humidity that does not
exceed 75°F and 55% R.H.

M4

M4E

Discharge Air °F

28

29

Evaporator °F

18

21

Unit Sizing °F

16

19

Btu/hr/ft**

M4

M4E

Parallel

1325

1270

Conventional

1405

1350

**For all refrigeration equipment other than
Husssmann, use conventional BTU values.

DEFROST DATA

M4

M4E

Frequency (hr)

6

6

Defrost Water (lb/ft/day)

8

8

(±15% based on case configuration and
product loading.

O

FFTIME

M4

M4E

Temp Term °F

48°F

48°F

Failsafe Minutes

25

30

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close 48°F – open 33°F

CONVENTIONALCONTROLS

Low Pressure Backup Control

M4

M4E

CI/CO**

12/2°F 14/4°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lbs)***

M4

M4E

8 ft

2.3

2.7

12 ft

3.3

3.9

***This is an average for all refrigerant
types actual refrigerant charge may vary 
by approximately half a pound.

Length (in.) Added to Lineup 
by Each End or Insulated 
Partition

1

/

2

Impact 

M4

Meat and Delecatessen

Multi-deck, 4 Display Levels

Dimensions shown as inches and (mm).

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

Содержание IMPACT M4

Страница 1: ...otor B 0411744 Standard Non adjustable 2 Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Note Changed items have been underlined Merchandisers D E E A E C D B M4 Data Sheet Set P N 0378419C NSF Certified December 2003 Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace wi...

Страница 2: ...between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Electrical Field Wiring connection point B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of c...

Страница 3: ...ration and product loading OFFTIME M4 M4E Temp Term F 48 F 48 F Failsafe Minutes 25 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure Backup Control M4 M4E CI CO 12 2 F 14 4 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser D...

Страница 4: ... 120V 60Hz 3 00 4 40 Export 230V 50Hz 1 72 2 48 With Energy Efficient Fans 120V 60Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1 Row ...

Страница 5: ...ector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All component...

Страница 6: ...models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch ...

Отзывы: