REFRIGERANT

The correct type of refrigerant will be stamped
on each merchandiser’s serial plate. The case
refrigeration piping is leak tested, factory
sealed and pressurized. Before making refrig-
eration hookups, depress the universal line
valve to ensure that coils have maintained
pressure during shipment.

REFRIGERANT PIPING

Connection Location

The refrigerant line connections are at the right-
hand end of the merchandiser (as viewed from the
front) beneath the display pans. A sticker marks
the location of the connection “pod.” The installer
must saw a hole through the pod to exit the case.

After connections have been made, seal this outlet
thoroughly. Seal both the inside and the outside.
We recommend using an expanding polyurethane
foam insulation.

Multiplexing

Piping of merchandisers operating on the same
refrigeration system may be run from merchandis-
er to merchandiser. 

D

O NOT RUN REFRIGERANT

LINES THROUGH

MERCHANDISERS THAT ARE

NOT

ON THE

SAME

REFRIGERATION

SYSTEM

BRANCH

as this may result in poor refrigeration

control and compressor failure.

Interconnecting piping inside the merchandiser
must be located as shown below to allow room for
lifting the hinged fan plenums and for clearance
beneath the display pans. Or the interconnecting
piping may be run outside the case in the raceway
area shown.

Line Sizing

Refrigerant lines should be sized as shown on the
refrigeration legend that is furnished for the store
or according to ASHRAE guidelines. Refer to
information on the next page for branch line pip-
ing of Hussmann Equipment.

Oil Traps

P-traps (oil traps) must be installed at the base of
all suction line vertical risers. 

Pressure Drop

Pressure drop can rob the system of capacity. To
keep the pressure drop to a minimum, keep the
refrigerant line run as short as possible using a
minimum number of elbows. Where elbows are
required,

USE LONG RADIUS ELBOWS ONLY

.

REFRIGERATION / ELECTRICAL

Refrigeration lines are under pressure and

should be depressurized before attempting

to make any connections.

WARNING

!

When brazing pipes be sure to use the 

insulation blanket shipped with the 

merchandiser to prevent damage to the 

plastic case bottom.

CAUTION

!

Fan Plenum

Pan

Pod

Piping
Locations

Содержание Impact F2

Страница 1: ...Meat and Seafood Wall Merchandiser NSF Certified Installation Operation Manual Shipped With Case Data Sheets P N 424382A Impact Series February 2001 Merchandisers IM PORTANT Keep in store for future...

Страница 2: ...figuration 4 2 MAINTENANCE Care and Cleaning 5 1 Cleaning Under Merchandiser 5 2 Removing Scratches from Bumper 5 2 Cleaning Honeycomb Assemblies 5 2 Removing Interior Back Panels 5 2 SERVICE Replacin...

Страница 3: ...conditioning electric fans open doors or windows etc to create air currents around the merchandisers Product should always be maintained at proper temperature This means that from the time the produc...

Страница 4: ...EVELING Merchandisers must be installed level to ensure proper operation of the refrigeration system and to ensure proper drainage of defrost water Ice may build up from defrost water not draining out...

Страница 5: ...a panel lift it up from its bottom edge and out No tools are required Apply Gaskets 1 Apply 15 8 in 31 mm gasket in the horizon tal recess across the bottom and up the front of the merchandiser as sho...

Страница 6: ...the case 2 Use field supplied silicone to fill any gaps between the front support brackets A B C D Alignment Pins Tighten in order shown Butyl Tape IMPORTANT Do not stretch gasket especially around co...

Страница 7: ...ry installed glass trim and bumpers from cases as follows a Standard plastic glass trim is friction fit Start at left end and lift up moving to right end Pry tools will damage trim b Remove upper and...

Страница 8: ...y damage the trim 8 Once all except the last sections of upper bumper and glass trim have been installed refrigerate the case line up for at least six 6 hours The last sections of upper bumper and gla...

Страница 9: ...E SAME REFRIGERATION SYSTEM BRANCH as this may result in poor refrigeration control and compressor failure Interconnecting piping inside the merchandiser must be located as shown below to allow room f...

Страница 10: ...1829 mm from the left hand end facing front of the merchandiser The optional refrigeration thermostat is located 5 ft 1524 mm from the left hand end just past the raceway On wide island models the th...

Страница 11: ...ectrical raceway or Handy Box FIELD WIRING Field wiring must be sized for component amperes stamped on the serial plate Actual ampere draw may be less than specified Field wiring from the refrigeratio...

Страница 12: ...by a colored plastic band neutral wire for each circuit has either White insulation or a White plastic sleeve in addition to the color band PINK REFRIG THERMOSTAT LOW TEMP ORANGE OR LIGHT BLUE REFRIG...

Страница 13: ...inage 1 Never use drip piping smaller than the nominal diameter of the pipe or water seal supplied with the merchandiser 2 When connecting drip piping the water seal must be used as part of the drip p...

Страница 14: ...on will be necessary This is to ensure a good and secure installation 2 Apply a good silicone type sealer along the bottom of the splashguard Sealant must be removed and replaced when servicing OPTION...

Страница 15: ...IME SHOULD MERCHANDISERS BE STOCKED BEYOND THE LOAD LIMITS INDICATED DO NOT BLOCK HONEYCOMBS STOCKING Product should NOT be placed in merchandisers until case is at proper operating temperature Proper...

Страница 16: ...together NOTE Some price tag molding styles are pop riv eted to the shelf In these instances the alignment strips must be cut in half before insertion MULTI DECK SHELF CONFIGURATION The bottom display...

Страница 17: ...Remove the product and all loose debris to avoid clogging the waste outlet Store product in a refrigerated area such as a freezer Remove only as much product as can be taken to the freezer in a timel...

Страница 18: ...MBLIES Honeycombs should be cleaned every six months Dirty honeycombs will cause merchandisers to perform poorly The honeycombs may be cleaned with a vacuum cleaner Soap and water may be used if all w...

Страница 19: ...ET For access to these fans 1 Turn off power to the merchandiser 2 Remove wire racks and bottom display pans 3 Disconnect fan motor from wiring harness 4 Remove 6 screws attaching fan assembly to plen...

Страница 20: ...ect direction Make sure fan blade spins freely Electric Defrost Thermostat Evaporator Fans Multiglass with Anti Sweat Heater Ballast Refrigeration Thermostat Fluorescent Lamps Reheat Heater Anti Sweat...

Страница 21: ...ve 4 screws holding fan assembly 5 Remove and replace fan assembly 6 Replace screws in fan assembly 7 Reconnect wiring 8 Verify that fan motor is working and fan blade is turning in the correct direct...

Страница 22: ...eplace heater 6 Reconnect heater to wiring harness 7 Replace clips and screws Turn power on 8 Verify that new heater is working properly 9 Replace back panels wire racks display pans and shelves NOTE...

Страница 23: ...ps for the new heater 6 Remove screws holding bushing box Slide old heater out and remove wire from bushing 7 Feed wire of new heater through bushing and slide heater into place 8 Replace clips and sc...

Страница 24: ...heater 7 Clean surface before applying new adhesive backed heater 8 Reconnect heater to wiring harness 8 Replace honeycomb and refasten honeycomb assembly Turn power on 9 Verify that new heater is wo...

Страница 25: ...emove it from the left and right channels 7 To install new glass have one person hold each end of the thermopane glass assembly with lead wires to left Carefully feed heater lead wires through insulat...

Страница 26: ...rchandis er meet pull back and down until the panel swings freely 5 Replace ballast and reassemble parts in reverse order 6 Reconnect the electrical power REPLACING FLUORESCENT LAMPS Fluorescent lamps...

Страница 27: ...D DRAIN FITTING The following procedure is for the field repair of a broken drain fitting 1 Use a drill with a 17 8 in 48 mm hole saw to drill out the bottom of the drain fitting Be sure to drill comp...

Страница 28: ...Irving TX 75062 Phone 1 800 527 9916 NOTE Hussmann Aluminum melts at 1125 F 607 C Aladdin 3 in 1 rod at 732 F 389 C X Ergon Acid core at 455 F 235 C Technique 1 Locate Leak 2 REMOVE ALL PRESSURE 3 Bru...

Страница 29: ...ct your Hussmann representative Please include the model and serial number of the product The full product warranty is available from our website www hussmann com Hussmann Corporation Corporate Headqu...

Отзывы: