Thermostat Bulb

Location

(Optional

Lights)

D

A

C

B

P/N 0453555A

ESGMS

Data Sheet Set

P/N  0453555A

NSF

®

Certified

October  2005

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Note: Changed items have been underlined.

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

0404551

Fan Motor, Ambient (120V)

(1)

0404552

Fan Motor, Ambient (230V)

B.

0353949

Optional Adjustable 

(2)

Refrigeration Thermostat

Item

Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

C.

0355716

Ballast, Electronic, 

2 lamps

(120V)

(3)

C.

0355398

Ballast, Electronic,

3 lamps

(120V)

(4)

C.

0440215

Ballast, Electronic, 

2 lamps

(230V 50-60 Hz) 

(3)

C.

0428652

Ballast, Electronic,

3 lamps

(230V 50-60 Hz)

(4)

0385104

Ballast Transformer
(230V 50-60 Hz,  per ballast)

D.

Fluorescent Lamp

(5)

Replace with like fixtures

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Содержание ESGMS

Страница 1: ...Part Description Wiring Item LAMPS AND BALLASTS C 0355716 Ballast Electronic 2 lamps 120V 3 C 0355398 Ballast Electronic 3 lamps 120V 4 C 0440215 Ballast Electronic 2 lamps 230V 50 60 Hz 3 C 0428652 Ballast Electronic 3 lamps 230V 50 60 Hz 4 0385104 Ballast Transformer 230V 50 60 Hz per ballast D Fluorescent Lamp 5 Replace with like fixtures We reserve the right to change or revise specifications ...

Страница 2: ... 37 940 NA NA NA Electrical Service Electrical Field Wiring connection point C Length of electrical raceway 38 3 4 984 29 5 8 752 41 3 4 1060 41 3 4 1060 RH End of case to center of farthest knockout 10 3 8 264 10 254 10 3 8 264 10 1 4 260 Back of case to center of end knockout 3 5 8 92 3 5 8 92 3 5 8 92 3 5 8 92 B RH End of case to RH end of raceway 5 127 5 127 5 127 5 127 Waste Outlet D RH End o...

Страница 3: ...Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 4 ft 0 8 6 ft 1 2 8 ft 1 5 12 ft 2 0 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End Partition in 1 3 of 6 P N 0453555A 24 3 4 629 8 1 4...

Страница 4: ...5 45 68 Energy Efficient 120V 60hz N A Export 230V 50 hz 0 15 0 30 0 30 0 45 25 50 50 75 Constant On Anti sweat Heaters N A Cycling Anti sweat Heaters N A Minimum Circuit Ampacity With Standard Fans 120V 60hz 0 46 0 72 0 72 0 98 With Energy Efficient Fans 120V 60hz N A With Export Fans 230V 50 hz 0 35 0 50 0 50 0 65 Maximum Over Circuit Protection 120V 20 Maximum Over Circuit Protection 230V 15 St...

Страница 5: ...B G N E C TAGS MAROON BAND Refrigeration Thermostat To Condensing Unit Field Installed 2 BROWN BAND Fans BROWN BAND 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only 1 4 ft case has 1 Fan 6 ft case has 2 Fans 8 ft case has 2 Fans 12 ft case has 3 Fans Ligh...

Страница 6: ...nd the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only 3 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B W R R B L B L R B L R R B L B L R B L B L B G G G G G G G 3 5 5 5 5 R R B L B L R B L B L G G G 3 5 5 5 Optional Ledge Light Circuit or Optional Rail Light Circuit HUSSMANN CORPORATION Bridgeton MO...

Отзывы: