background image

D5X-HEP 

Technical Data Sheet 

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

6 of 8

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

4

4

3

3

3

4

4

4

4

4

4

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

4

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

Standard Lighting 

 1 Row Canopy 

 Optional Lighting 

 2 Row Canopy 

                                      3 Row Canopy

4

3

4

4

Connector

W

B

BL

BL

R

BL

R

R

R

 Optional Lighting 

 1 Row Rail

B

4 ft

6 ft or 8 ft

12 ft

4 ft

6 ft or 8 ft

12 ft

Refrigeration 

Thermostat

2

To 
Condensing 
Unit

}

Light Blue

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 1 Fan 

 

 2 Fans 

 

 2 Fans 

 

 3 Fans

4 ft 
6 ft 
8 ft 

12 ft

12 ft

Fan Wiring
Offtime Defrost

Light Circuits

Содержание D5X-HEP

Страница 1: ...B 4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part Description Wiring Item THERMOSTATS B Optional Adjustable Refrigeration Thermostat 2 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY C Ballast Electronic 3 0480130 2 lamps...

Страница 2: ...xternal legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area 24 6...

Страница 3: ...p Control CI CO D5X HEP 19 F 9 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb D5X HEP 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 31 5 8 804 4 3 4 120 30 1 4 768 33 1 2 851 30 1 4 768 61 1549 42 1 8 1069 46 7...

Страница 4: ... Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1 53 2 31 89 177 177 255 1 Row Rail Light 0 26 ...

Страница 5: ... 87 m3 m ARI Total Display Area 3 Sq Ft Ft 4 13 ft2 ft 1 26 m2 m Shelf Area 4 Sq Ft Ft 9 89 ft2 ft 3 02 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Leng...

Страница 6: ...wo Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 4 3 4 4 Connector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft Refrigeration Thermostat 2 To Condensing Unit Light Blue 1 2 3 Fans 120...

Страница 7: ... components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft case Connector 4 3 4 4 4 4 B W Connector 6 ft or 8 ft case 12 ft case BL BL R BL R BL R BL W R W R B R BL BL R 3 B BL BL BL BL BL R R R R R 4 3 4 4 4 4 B W BL BL R BL R BL R BL W R W R B R BL BL R 3...

Страница 8: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3 ...

Отзывы: