Hussmann Chino Q2-SPN Скачать руководство пользователя страница 1

Q2-SPN

DELI SELF SERVICE 

CASE

 

P/N Q2-SPN-1218

INSTALLATION & OPERATION GUIDE

/CHINO

Q2-SP

DELI SELF SER

VICE CASE

REV

. 1218

Installation 

 

& Operation 

 

Manual

Содержание Chino Q2-SPN

Страница 1: ...Q2 SPN DELI SELF SERVICE CASE P N Q2 SPN 1218 INSTALLATION OPERATION GUIDE CHINO Q2 SP DELI SELF SERVICE CASE REV 1218 Installation Operation Manual ...

Страница 2: ...tion within 15 days and retain all packaging The carrier will supply inspection report and required claim forms Shortages Check your shipment for any possible shortages of material If a shortage should exist and is found to be the responsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier immediately and request an inspection Hussmann Chino wi...

Страница 3: ...uctions 2 3 Cut and Plan Views 4 4 Installation 5 5 Plumbing 8 6 Refrigeration 9 8 Finishing Touches 11 9 User Information 12 13 Troubleshooting Guide 17 7 Electrical 10 10 Maintenance 13 11 Wiring Diagrams Index 15 12 Wiring Diagrams 16 ...

Страница 4: ...5 17 N A N A N A 45 OS 1 6 7 25 0 12 8 N A N A 0 04 5 0 06 7 0 10 12 0 10 11 N A N A N A 90 OS 3 6 7 25 0 36 24 N A N A 0 04 5 0 04 5 0 09 10 0 25 29 N A N A N A 30 OS 1 0 14 20 N A N A 0 04 5 0 04 5 0 09 10 0 15 17 N A N A N A OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT CASE ENERGY USAGE DATA AMPS WATTS AMPS WATTS AMPS WATTS 4 N A N A N A N A N A N A 5 N A N A N A N A N A N A 6 N A N A N A N A N A N...

Страница 5: ...to shipment to insure the closest possible fit when cases are joined in the field When joining use a carpenters level and adjust legs accordingly The legs on the Q2 SPN are adjustable and do not require shims Simply screw the leg up or down to adjust height 1 Using case blueprints measure off and mark on the floor the exact dimensions of where the cases will sit Snap chalk line for front and back ...

Страница 6: ...icone if necessary Remove tape applied on line 4 11 Remove front back and end shipping braces Installation Cont d Bumper Installation Instructions Step 1 Make sure the aluminum channel and end caps are installed Step 2 Use silicone lubricant to help the bumper slide into the channel Step 3 Starting on one end while inserting the bumper push it up against the end cap to prevent the bumper from shri...

Страница 7: ...at all case to case gaps are acceptable 5 Install Bulkhead Caps see page 2 TOP BOLT LOCATION FRONT BOLT LOCATION REAR BOLT LOCATION BOLT HOLE BOLT HOLE BOLT HOLE ALIGNMENT PIN ALIGNMENT PIN TOP BOLT PRIMARY ACCESS THROUGH CONDIMENT PANS TOP BOLT SECONDARY ACCESS THROUGH INTERIOR PANELS OR HONEYCOMB WHEN SECTION HAS NO CONDIMENT PANS ACCESS FROM UNDERSIDE FRONT BOLT ACCESS BY REMOVING FRONT BODY PA...

Страница 8: ...oor drains should be at least 14 off the center of the case to allow use of the P TRAP pipe section Never use two water seals in series in any one line Double P TRAPS in series will cause a lock and prevent draining 3 Always provide as much down hill slope fall as possible 1 8 per foot is the preferred minimum PVC pipe when used must be supported to maintain the 1 8 pitch and to prevent warping 4 ...

Страница 9: ...om case Remove pans TX valve mechanical only and drain are located under the pans within the case Electronic The electronic expansion valve master and slave cylinder s are located within the electrical access panel s in the rear of case Rear panels lift up and out NOTE Duplex receptacles must be detached before removing rear panels Electronic Expansion Valve Optional A wide variety of electronic e...

Страница 10: ...YS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT This includes but not limited to Fans Heaters Thermostats and Lights Field Wiring and Serial Plate Amperage Field Wiring must be sized for component amperes printed on the serial plate Actual ampere draw may be less than specified Field wiring from the refrigeration control panel to the merch...

Страница 11: ...llet at a slight angle that forces the bumper back into itself to prevent stretching The installation can be made easier by applying a paraffin block to the retainer grooves Installing Splashguard After merchandisers have been leveled and joined and all drip piping electrical and refrigeration work has been completed install the splashguards Splashguards may be sealed to the floor using a vinyl co...

Страница 12: ...anufacturer s directions It is essential to establish and regulate cleaning procedures This will minimize bacteria causing discoloration which leads to degraded product appearance and significantly shortening product shelf life Soap and hot water are not enough to kill this bacteria A sanitizing solution must be included with each cleaning process to eliminate this bacteria 1 Scrub thoroughly clea...

Страница 13: ...replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR Copper Coils The copper coils used in Hussmann merchandisers may be repaired in the field Materials are available from local refrigeration wholesalers Hussmann recommends using 15 Sil Fos for repairs Tips and Troubleshooting Before calling for service check the following 1 Check electrical power supply to the equipment ...

Страница 14: ...Lines Some stainless steels come with visible polishing lines or grain When visible lines are present you should ALWAYS scrub in a motion that is parallel to them When the grain cannot be seen play it safe and use a soft cloth or plastic scouring pad 3 Use Alkaline Alkaline Chlorinated or Non chloride Containing Cleaners While many traditional cleaners are loaded with chlorides the industry is pro...

Страница 15: ...003959 Q2 SP N 5R W OP TIONAL TOP LIGHT 5 3064454 Q2 SP N6 R 6 1H95151 Q2 SPN 8R 8 3008496 Q2 SP N 10R W OP TIONAL TOP LIGHT 10 3003958 Q2 SP N12 R 12 3013450 Q2 SPN 22 50 R 22 5 3070614 Q2 SPN 45OS 45 2H21329 Q2 SPN 30OS 30 2H21307 Q2 SPN 90OS 90 2H21327 11 Wiring Diagrams Index ...

Страница 16: ...25 01 0710 LIQUID SOLENOID 14A 120VAC INCOMING POWER 120 VAC 60 Hz 15 0 L1 120 V LOADING GFCI DUPLEX 125 01 3178 NOTE FOR GFCI PROTECTION IF MORE THAN ONE SINGLE RECEPTACLE IS USED IN CONJUNCTION WITH A GFCI DUPLEX RECEPTACLE DOWNSTREAM ON THE LOAD SIDE THE SUM OF ALL RECEPTACLES SHOULD NOT BE MORE THAN 15A LOAD SIDE POWER RECEPTACLE 125 01 0443 OPTIONAL 120 VAC 60 Hz CIRCUIT 2 optional BLK 14 WHT...

Страница 17: ...WER 120 VAC 60 Hz 15 0 L1 120 V LOADING GFCI DUPLEX 125 01 3178 NOTE FOR GFCI PROTECTION IF MORE THAN ONE SINGLE RECEPTACLE IS USED IN CONJUNCTION WITH A GFCI DUPLEX RECEPTACLE DOWNSTREAM ON THE LOAD SIDE THE SUM OF ALL RECEPTACLES SHOULD NOT BE MORE THAN 15A LOAD SIDE POWER RECEPTACLE 125 01 0443 OPTIONAL 120 VAC 60 Hz CIRCUIT 2 optional BLK 14 WHT 14 GRN 14 BUNDLE YELLOW ALL SINGLE RECEPTACLES T...

Страница 18: ...0 L1 120 V LOADING GFCI DUPLEX 125 01 3178 NOTE FOR GFCI PROTECTION IF MORE THAN ONE SINGLE RECEPTACLE IS USED IN CONJUNCTION WITH A GFCI DUPLEX RECEPTACLE DOWNSTREAM ON THE LOAD SIDE THE SUM OF ALL RECEPTACLES SHOULD NOT BE MORE THAN 15A LOAD SIDE POWER RECEPTACLE 125 01 0443 OPTIONAL 120 VAC 60 Hz CIRCUIT 2 optional BLK 14 WHT 14 GRN 14 BUNDLE YELLOW ALL SINGLE RECEPTACLES TO BE TIED TO DUPLEX G...

Страница 19: ... 14A 120VAC INCOMING POWER 120 VAC 60 Hz 15 0 L1 120 V LOADING GFCI DUPLEX 125 01 3178 NOTE FOR GFCI PROTECTION IF MORE THAN ONE SINGLE RECEPTACLE IS USED IN CONJUNCTION WITH A GFCI DUPLEX RECEPTACLE DOWNSTREAM ON THE LOAD SIDE THE SUM OF ALL RECEPTACLES SHOULD NOT BE MORE THAN 15A LOAD SIDE POWER RECEPTACLE 125 01 0443 OPTIONAL 120 VAC 60 Hz CIRCUIT 2 optional BLK 14 WHT 14 GRN 14 BUNDLE YELLOW A...

Страница 20: ... 120 V LOADING GFCI DUPLEX 125 01 3178 NOTE FOR GFCI PROTECTION IF MORE THAN ONE SINGLE RECEPTACLE IS USED IN CONJUNCTION WITH A GFCI DUPLEX RECEPTACLE DOWNSTREAM ON THE LOAD SIDE THE SUM OF ALL RECEPTACLES SHOULD NOT BE MORE THAN 15A LOAD SIDE POWER RECEPTACLE 125 01 0443 OPTIONAL 120 VAC 60 Hz CIRCUIT 2 optional BLK 14 WHT 14 GRN 14 BUNDLE YELLOW ALL SINGLE RECEPTACLES TO BE TIED TO DUPLEX GFCI ...

Страница 21: ...OWER 120 VAC 60 Hz 15 0 L1 120 V LOADING GFCI DUPLEX 125 01 3178 NOTE FOR GFCI PROTECTION IF MORE THAN ONE SINGLE RECEPTACLE IS USED IN CONJUNCTION WITH A GFCI DUPLEX RECEPTACLE DOWNSTREAM ON THE LOAD SIDE THE SUM OF ALL RECEPTACLES SHOULD NOT BE MORE THAN 15A LOAD SIDE POWER RECEPTACLE 125 01 0443 OPTIONAL 120 VAC 60 Hz CIRCUIT 2 optional BLK 14 WHT 14 GRN 14 BUNDLE YELLOW ALL SINGLE RECEPTACLES ...

Страница 22: ...ASSING WIRES THROUGH METAL HOLES A GROMMET MUST BE USED A SHEET 1 OF 1 CIRCUIT 1 L1 LOADING 0 7 120V BLACK 14 WHITE 14 SWITCH TOGGLE 2 125 01 0307 120 VAC 60 Hz BUNDLE BROWN L1 N MCA 0 60A MOP 15A BUNDLE BLACK WHITE N L BLK 14 MOP 15A WHT 14 T STAT 225 01 0707 LIQUID SOLENOID 14A 120VAC M M EVAP FAN MOTOR 2 0477653 4W 12A 120VAC CANOPY SHELF LIGHTS OPTIONAL LEDGE LIGHTS OPTIONAL 120 VAC 60 Hz BUND...

Страница 23: ...EVISION HISTORY NOTES CASE MUST BE GROUNDED A SHEET 1 OF 1 CIRCUIT 1 L1 LOADING 0 24 120V BLACK 14 WHITE 14 SWITCH TOGGLE 125 01 0307 120 VAC 60 Hz BUNDLE ORANGE L1 N MCA 0 07A MOP 15A 120 VAC 60 Hz BUNDLE BROWN L1 N MCA 0 29A MOP 15A BUNDLE BLACK WHITE N L BLK 14 MOP 15A WHT 14 T STAT 225 01 0707 LIQUID SOLENOID 225 01 1332 16A 120VAC EVAP FAN MOTOR 125 01 2012 20W 23A 120VAC M BLK 14 WHT 14 OPTI...

Страница 24: ...EVISION HISTORY NOTES CASE MUST BE GROUNDED A SHEET 1 OF 1 CIRCUIT 1 L1 LOADING 0 24 120V BLACK 14 WHITE 14 SWITCH TOGGLE 125 01 0307 120 VAC 60 Hz BUNDLE ORANGE L1 N MCA 0 01A MOP 15A 120 VAC 60 Hz BUNDLE BROWN L1 N MCA 0 29A MOP 15A BUNDLE BLACK WHITE N L BLK 14 MOP 15A WHT 14 T STAT 225 01 0707 LIQUID SOLENOID 225 01 1332 16A 120VAC EVAP FAN MOTOR 125 01 2012 20W 23A 120VAC M BLK 14 WHT 14 OPTI...

Страница 25: ...ST BE GROUNDED B SHEET 1 OF 1 CIRCUIT 1 L1 LOADING 0 83 120V BLACK 14 WHITE 14 SWITCH TOGGLE 125 01 0307 120 VAC 60 Hz BUNDLE ORANGE L1 N MCA 0 01A MOP 15A 120 VAC 60 Hz BUNDLE BROWN L1 N MCA 0 45A MOP 15A BUNDLE BLACK WHITE N L BLK 14 MOP 15A WHT 14 T STAT 225 01 0707 LIQUID SOLENOID 225 01 1332 16A 120VAC EVAP FAN MOTOR 3 0477653 7W 12A 120VAC M BLK 14 WHT 14 OPTIONAL M M BLUE RED LED DRIVER LIG...

Страница 26: ... blocked make sure debris is not blocking the intake section Coil close offs are not installed Inspect coil to make sure these parts are on the case Condensing coil or evaporator coil is clogged or dirty Clean coil Case temperature is too cold The t stat temp is set too low Check settings See Technical Specifications section Ambient conditions may be affecting the case operation Check case positio...

Страница 27: ...ng over Return air is blocked make sure debris is not blocking the intake section Coil close offs are not installed Inspect coil to make sure these parts are on the case Large gap is visible on bottom of front glass or glass can t be opened because it is too low Glass Height adjusters need to be adjusted See Glass Adjustment section Large gaps are visible in between glass panels or glass rubs agai...

Страница 28: ...red more of a right to know law than a pure product safety law When used as designed Hussmann believes that our products are not harmful We provide the Proposition 65 warning to stay in compliance with California State law It is your responsibility to provide accurate Proposition 65 warning labels to your customers when necessary For more information on Proposition 65 please visit the California S...

Страница 29: ...__________________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _________...