Hussmann C3X-LGE Скачать руководство пользователя страница 1

P/N 0477979_C

B

E

C

E

F

A

F

D

G

H

C3X-LGE

Technical Data Sheet

P/N 0477979_C

NSF

®

Certified

March  2008

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

4 Ft, 8 Ft & 12 Ft

A.

12W Standard

Fan Assembly 

(1)

0047000

Fan Motor, Evaporator
(MO.4410103)

0461805

Fan Blade (FB.4780446)

12W Energy Efficient

Fan Assembly 

(1)

0477655

Fan Motor, Evaporator 
(MO.4410546)

0461805

Fan Blade (FB.4780446)

6 Ft Only 

A.

7W Standard 

Fan Assembly  

(1)

0058698

Fan Motor, Evaporator
(MO.4410102)

0142780

Fan Blade (FB.0142780)

7W Energy Efficient

Fan Assembly 

(1)

0477654

Fan Motor, Evaporator
(MO.4410545)

0142780

Fan Blade (FB.0142780)

T

HERMOSTATS

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat
(CT.0411744)

Item Part #

Description

Wiring Item #

T

HERMOSTATS

(C

ONTINUED

)

C. Optional Adjustable Refrigeration Thermostat (3)

H

EATERS

D.

Canopy Anti-Sweat Heater

(4)

0488621

4 ft (HE.4850616)

0488622

6 ft (HE.4850617)

0488623

8 ft (HE.4850618)

0488624

12 ft (HE.4850619)

L

AMPS

. B

ALLASTS

, LED F

IXTURES AND

P

OWER

S

UPPLY

E. Ballast, Electronic

(5)

0480130

2 lamps (BA.4481676)

0480131

3 lamps (BA.4481654)

0480132

4 lamps (BA.4481677)

F.

Fluorescent Lamp

(6)

Replace with like fixtures

G. 0501213

Power Supply (EP.4481861)

(7)

H.

LED Fixture

(8)

Replace with like fixtures

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Note:  Revision C changes ballast (

Page 1

); adds optional LED lighting (

Pages 1, 3, 4, 8

); adds capacity and weight (

Page 5

).

Содержание C3X-LGE

Страница 1: ...0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 Item Part Description Wiring Item THERMOSTATS CONTINUED C Optional Adjustable Refrigeration Thermostat 3 HEATERS D Canopy Anti Sweat Heater 4 0488621 4 ft HE 4850616 0488622 6 ft HE 4850617 0488623 8 ft HE 4850...

Страница 2: ...ween edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of st...

Страница 3: ...t lamps DEFROST DATA C3X LGE Frequency hr 6 Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME C3X LGE Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control C3X LGE CI CO 14 F 4 F Indoor Unit Only Pressure Defrost Termination 48 F Use a T...

Страница 4: ...40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V 50 60Hz Standard 0 10 0 15 0 20 0 30 12 18 24 36 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 Fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 1 Row Rail Light NA Glass front does not accept...

Страница 5: ...RI Total Display Area 3 Sq Ft Ft 4 07 ft2 ft 1 24 m2 m Shelf Area 4 Sq Ft Ft 6 02 ft2 ft 1 84 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 ...

Страница 6: ...ft 8 ft 12 ft 12 ft 6 6 5 5 6 6 6 6 Optional Two Row Canopy Connector BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy B 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLE...

Страница 7: ...e 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 6 6 6 B W 6 ft or 8 ft case 12 ft case BL BL R BL BL BL R W R B R 5 BL BL BL R R R R 6 6 6 B W BL BL R BL BL BL R W R B R 5 BL BL BL R R R R C...

Страница 8: ...BL 8 8 R BL R BL R BL 8 8 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixtur...

Страница 9: ...ceptacle B Connector R BL R BL R BL R BL R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shel...

Страница 10: ...This case is designed for three 3 shelves The depth of the shelves used are critical to case performance The use of peg shelves is NOT recommended on C3X LGE cases Depth and angle requirements are listed below Top Shelf Shelf Depth Shelf Angle 12 inches 0º 10º 15º 30º 45º 14 inches 30º 45º Second Shelf Shelf Depth Shelf Angle 14 inches 0º 10º 15º 30º 45º 16 inches 30º 45º Third Shelf Shelf Depth S...

Страница 11: ... ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of light channel 2 Lower light channel which will pivot on hinge 3 Service or replace ballasts as required 4 Reassemble items as they were originally installed NOTE Rail lamp ballast is located in the ...