Menu system overview
>MENU
20 DEC 20:55
DRIVE CHOICES
CALIBRATE ARM
SET GEAR
[-]
SET DRIVE MODE
[-]
SET ROT. DIR.
[STANDARD]
SET FUSE
[-]
SET WATER VALVE
[-]
>>DRIVE CHOICES
20 DEC 20:55
20 DEC 20:55
CHANGE NUMBER WITH
STEP FORWARD WITH OK
09317
OK
>>SETTINGS
RUN TIME
TIME & DATE
[20:51 2010-01-12]
LANGUAGE
[ENGLISH]
SET UNITS
[METRIC]
RADIO CHANNEL
[0]
20 DEC 20:55
PAIR RADIO
SETTINGS
SERVICE
PRODUCT INFO
SET BLADE DIAM.
[800 mm]
9
10
11
12
13
14
4
5
6
7
8
1
15
16
2
3
Main menu
Submenu
Adjustment
1. "DRIVE
CHOICES"
4. "SET GEAR"
The wall saw has 2 mechanical gears:
1. (600-900 rpm)
2. (800-1200 rpm)
5. "SET DRIVE
MODE"
Set the necessary "DRIVE MODE" for the product:
• "BLADE" for wall sawing
• "WIRE" for wire cutting
• "CHAIN" for chain sawing
6. "SET ROT. DIR."
Stop the product before change of direction of the blade. Select be-
tween:
• "STANDARD"
• "REVERSE"
7. "SET FUSE"
To use full power output, the product must be connected to a 32 A fuse.
With a fuse that is lower rated, the power output must be lower to not
overload the fuse. Select the applicable fuse rated value that is related to
the connected product:
• 16A
• 25A
• 32A
8. "SET WATER
VALVE"
The water flow is adjusted with the ball valve at the water connector inlet.
Select correct water regulation:
• "ON" - The water valve is always open.
• "AUTO" - The water valve opens when the dial is turned from its
closed position.
8