16 COOLING SYSTEM
96
F00451-10
–
Position the motorcycle upright.
–
Place a suitable container under the water pump cover.
–
Remove screw
. Take off radiator cap
.
–
Completely drain the coolant.
–
Mount and tighten screw
with a new seal ring.
Guideline
Screw, water pump cover
M6
10 Nm (7.4 lbf ft)
16.5
Refilling coolant
Warning
Danger of poisoning
Coolant is toxic and a health hazard.
–
Keep coolant out of the reach of children.
–
Do not allow coolant to come into contact with the skin, the eyes and clothing.
–
Consult a doctor immediately if coolant is swallowed.
–
Rinse the affected area immediately with plenty of water in the event of contact with the skin.
–
Rinse eyes thoroughly with water and consult a doctor immediately if coolant gets into the eyes.
–
Change clothing if coolant spills onto your clothing.
F00452-10
Main work
–
Make sure that the screw
is tightened.
–
Stand the vehicle upright.
–
Pour coolant in up to measurement
above the radiator fins.
Guideline
10 mm (0.39 in)
Coolant
1.2 l (1.3 qt.)
Coolant (
–
Refit the radiator cap.
Finishing work
–
Take a short test ride.
–
Check the coolant level. (