15
15.7
15.8
WIRING HARNESS, BATTERY
Checkin the charging volta e
Condition
The battery must be fully functional and completely charged.
- Carry out the start procedure. (
!el
p. 11)
Measure the voltage between the specified points.
Measuring point
Plus
(+) - Measuring point
Ground
(-)
I
Charging voltage
5,000 rpm
113.5 ... 15.0 V
If
the displayed value is less than the specified value:
107
Check the plug-in connections from the alternator to the voltage regulator.
Checking the uiescent current
- Check the plug-in connectors from the voltage regulator to the wiring har-
ness.
- Check the stator winding of the alternator. (
0
p. 202)
If
the displayed value is greater than the specified value:
- Change the voltage regulator.
Preparatory work
- Switch off all power consumers and switch off the engine.
- Remove the seat. (
�
p. 76)
Main work
- Disconnect the negative cable from the battery.
- Measure the current between battery ground (-) and the negative cable.
•
Info
I
The value of the quiescent current applies only to vehicles in the original
state, i.e. without additional power consumers.
I
Maximum closed-circuit current
I<
1.0 mA
If
the measured value is higher than the specified value:
- Disconnect the voltage regulator from the wiring harness and perform the
measurement again.
Содержание FE 250 AU 2014
Страница 2: ......
Страница 87: ...12 FUEL TANK SEAT TRIM Remove the special tools Join the fuel hose connection 85 ...