Ambient temperature less then
40°C / 104ºF
Ambient temperature between
40-50°C / 104-122°F
Ambient temperature between
50-55°C / 122-131°F
Kit 3
It is not necessary to cool down
the air.
Pressure,
bar/PSI
6/87
Pressure,
bar/PSI
10/145
Flow, l/min or
cu ft/min
1700/60
Flow, l/min or
cu ft/min
2100/74.2
The noise level for Kit 2 and 3 is 115 dB.
Hydraulic system pressure
Type of pressure
DXR 145
Pressure, bar/PSI
DXR 275, DXR 305, DXR 315
Pressure, bar/PSI
Maximum pump pressure, tool/outriggers
250/3626
250/3626
Rotating function
180/2611
175/2466
Outriggers, down and up
250/3626 and 130/1885
250/3626 and 200/2901
Arm function
For DXR 275, DXR 305, DXR 315, the pressure
for the arm function is lower when you operate
with a steel shear. The pressure for steel shear is
shown in brackets.
200/2901
200/2901 (150/2167)
DXR 315: Telescopic arm, in and out
N/A
200/2901 and180/2611
Standby pressure
5
20±1 or 290±14.5
20±1 or 290±14.5
Hydraulic oil
Speak to the product manufacturer before you use a type of hydraulic oil that is not specified in this manual. The qual-
ity of the hydraulic oil that the product was supplied with is shown on the label on the product.
CAUTION:
The product can be damaged if different types of hydraulic oil are mixed. Do a check of
which quality of hydraulic oil the hydraulic system contains before you fill with hydraulic oil.
Grade
Min. start temperature,
°C/°F
Max. temperature, °C/°F
Ideal operation tempera-
ture, °C/°F
Mineral oil ISO VG32
-20/-4
75/167
35–60/95–140
Mineral oil ISO VG46
(standard)
6
-10/14
85/185
45–70/13–158
Mineral oil ISO VG68
-5/23
90/194
55–80/131–176
5
The pressure that the pump supply when no function is in operation and the circulation valve is closed.
6
DXR 275, DXR 305, DXR 315: Heat resistant products are filled with fire resistant hydraulic oil.
1401 - 002 - 15.10.2021
109