![HUSABERG FE 450 AUS Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/husaberg/fe-450-aus/fe-450-aus_repair-manual_2187561022.webp)
01/FORK, TRIPLE CLAMP
20
200685-10
–
Measure the run-out of the inner tube.
Inner tub run-out
≤
0.20 mm (
≤
0.0079 in)
» If the measured value is larger than the specified value:
–
Replace the inner tube.
200632-10
–
Check the outer tube for damage.
» If there is damage:
–
Replace the outer tube.
200665-10
–
Check the surface of the sliding bushing.
» If the bronze-colored layer
can be seen beneath the sliding layer
:
–
Replace the sliding bushing.
200666-10
–
Check the spring length.
Guideline
Spring length with preload spacer(s)
510 mm (20.08 in)
» If the measured value is greater than the specified value:
–
Reduce the thickness of the preload spacer.
» If the measured value is smaller than the specified value:
–
Increase the thickness of the preload spacer.
5.17
Assembling the compression damping fitting
Info
The steps are identical for both fork legs.
200704-11
–
Clamp the compression damping fitting in a bench vise using soft jaws.
–
Mount O-ring
and seal ring
.
–
Grease the O-ring.
Lubricant (T158) (
Содержание FE 450 AUS
Страница 2: ......
Страница 205: ...FAULT CODE 203 If the measured value corresponds to the specified value Contact customer service...
Страница 237: ...235...
Страница 243: ...WIRING DIAGRAM 241...
Страница 247: ...WIRING DIAGRAM 245...
Страница 253: ...WIRING DIAGRAM 251...
Страница 261: ...WIRING DIAGRAM 259...