CELL INSTALLATION
The chlorinator cell must be located last in the pipe work just prior to the return to the pool. If valves are installed between
the Chlorinator and the pool outlet, it is essential that they cannot deadhead the pump. If the pressure in the cell exceeds
150kPa and/or the water temperature exceeds 40 degrees C, the cell may fail.
WARNING: Never install the cell before the pump or heater.
The cell must be installed with the barrel unions underneath and the cell should be horizontal. Both 40mm and 50mm
fittings have been provided. Make sure that the o’rings are correctly fitted and the unions are done up tightly.
Direction of flow through the cell is critical – unit must be plumbed with the water entering the cell at the end closest to the
terminal connections (as indicated by flow direction label mounted on cell)
WARNING: It is essential that pipe work and equipment do not allow gases generated from the cell to
collect and build up.
Once the cell is located, connect the black multi-core cable to the cell. The blue wire must be connected to the blue
terminal. The cable is designed to come from below the cell. Make sure all connections are tight to ensure good contact.