![Hurco AB6 Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/hurco/ab6/ab6_installation-manual_2187300151.webp)
Installation Manual
2-112
Revision E
Hurco
External Power Source
Refer to the data plate affixed to the AB6 power cabinet to determine the
external power requirements for the system. The power cabinet is typically
factory wired to operate from either a 115 VAC (±10%), 50/60 Hz, single
phase electrical source or a 240 VAC, (±10%), 50/60 Hz, single phase
electrical source. Do not change the input voltage without also making the
appropriate changes to the AB6 power cabinet wiring.
The electrical wiring must conform to all local, state or provincial codes.
The external power source must be free of inductive loads that could cause
noise or spikes on the line. Dedicate the external power source to the AB6,
and leave it on at all times.
Figure 2-77. Inside View of IEC Power Entry Plug and Cover
Connect the external power source to the AB6 power cabinet via a 3-wire
IEC power entry plug. Use a size 18-gauge AWG wire for the incoming
power line consisting of a hot, neutral and ground wire.
Warning
After determining the correct input electrical voltage,
turn off the external power source. Failure to do so may
result in serious injury.