Hunza SAFETOUCH 150 LED Скачать руководство пользователя страница 1

SAFETOUCH 150 LED

INSTALLATION INSTRUCTIONS 

NOTE: THESE INSTRUCTIONS MUST NOT 

CONTRAVENE YOUR LOCAL ELECTRICAL AUTHORITY 

REGULATIONS, WITH WHICH ALL INSTRUCTIONS 

HERE IN MUST COMPLY.

PLEASE KEEP INSTRUCTIONS FOR FUTURE 

REFERENCE.

Remove the complete fixture from the packaging. If the canister 

and luminaire are to be installed separately detach the luminaire 

from the canister and place it back in the packaging and store 

securely.

If not discard the packing in an environmentally friendly way.

Dig a hole 30cm (12”) diameter and 40cm (16”)Deep. Place 

drainage material in the bottom of the hole to drain away water and 

stop water level build up. 

(See Fig. 1)

.

Sit mounting canister into the hole. Make sure that the top of the 

canister is flush and level with the finished floor or ground level

(see Fig. 2a)

.

Draw the power supply cable up through the centre of the canister 

ready for connection to the luminaire.

Place blue flange protector into the top of the canister and press 

firmly into place. This will protect the bronze or stainless steel 

flange as well as stopping debris filling the canister. If grout is to be 

used with tiles etc. then remove the flange protector before grout-

ing is started.

NOTE: Do not backfill with stones, scoria or any material that 

will leave air gaps next to the canister.

Concrete is strongly recommended to backfill the canister 

hole. Concrete will conduct away 40% more heat than soil.

Fig. 2a

 Fig. 1

For Direct bury. Make a waterproof connection with the Input 

cables.

Place the luminaire into the hole. Make sure the flange is flush 

with the ground level and then back fill around the luminaire. 

Compact the surrounding substrate to ensure good heat 

conductivity. Place drainage material in the bottom of the hole to 

drain away water and stop water level build up. 

(see Fig. 2)

.

DIRECT BURY OPTION

CANISTER OPTION

Fig. 2