background image

 

PowerView® Roller Blind 230VAC

Programming with Remote control

The PowerView® M40T tubular motor is suited to be used with EOS® 500 Roller Blinds from Hunter Douglas.

1. Delivery condition

As standard, no remote control or hub is connected to the motor. No limits are set. Motor is default set to 

ro

ller blind

 motor type. 

IMPORTANT!

Factory fresh motors do not have default limits set. Limits must be set to enable normal operation. If
operated without limits, the shade could be damaged by rolling over the top or wrapping backwards on
the roller.

1.2. Network reset

This procedure will erase all network data stored in the motor, including Network ID and Group assignments.
It will not clear the end limits. Completing a Network reset will prevent a PowerView® remote or App from
operating the window covering until it is reprogrammed.

Page 1 of 18

version: 1.0

Содержание PowerView M40T

Страница 1: ...T Factory fresh motors do not have default limits set Limits must be set to enable normal operation If operated without limits the shade could be damaged by rolling over the top or wrapping backwards...

Страница 2: ...gn a blind to group 1 1 2 1 Press and hold the manual control button on the motor for 12 seconds The blind will jog 1x at 6 seconds and a second time at 12 seconds 1 2 2 Release the manual control but...

Страница 3: ...steps 2 4 and 2 5 within 3 seconds 2 1 Locate the manual control button on your blind 2 2 Press and hold the stop button for 4 seconds Keep pressing until the remote lights start blinking 2 3 Press th...

Страница 4: ...6 Release the manual control button 2 7 The blind will jog 2x to indicate it has joined the group 2 8 Press and hold the stop button for 4 seconds The remote will exit programming mode automatically...

Страница 5: ...direction has to be checked and reversed if needed If the top or bottom Limit is already set and the motor direction has to be reversed perform a reset before continuing 3 1 Deselect all GROUP number...

Страница 6: ...again 3 2 Check and con rm IMPORTANT Watch out to perform steps 3 2 1 and 3 2 2 immediately after each other to avoid mechanical damage Carefully read them rst before executing 3 1 3 Press and releas...

Страница 7: ...pen top limit Note It is important to have the fabric of the blind tight around the tube 3 2 1 Press the arrow down button to check motor direction 3 2 2 A If the blind moves upwards repeat steps 3 1...

Страница 8: ...and release of the button will toggle between Up Stop and Down 4 1 2 Use the open stop and close buttons to ne tune the blind to the desired position 4 1 3 Press and hold the stop button for 6 second...

Страница 9: ...teps 4 1 6 and 4 1 7 within 3 seconds 4 1 4 Press and hold the manual control button 4 1 5 Press the open button The blind will jog 2x to acknowledge the limit is set 4 1 6 Release the manual control...

Страница 10: ...tton for 6 seconds The remote will exit programming mode automatically after 20 seconds Keep pressing until the remote lights stop blinking 4 1 8 The top limit is set 4 2 1 Use the manual button on th...

Страница 11: ...pen stop and close buttons to ne tune the blind to the desired position 4 2 3 Press and hold the stop button for 6 seconds DO NOT select a group on the remote Keep pressing until the remote lights sta...

Страница 12: ...mit is set 4 2 6 Release the manual control button 4 2 7 Press and hold the stop button for 6 seconds The remote will exit programming mode automatically after 20 seconds Keep pressing until the remot...

Страница 13: ...t and repeat step 4 2 Close limit bottom 5 Clearing end limits 5 1 Clear top limit IMPORTANT Watch out to perform steps 6 1 2 and 6 1 3 within 3 seconds 5 1 1 Deselect all Group number on the remote 5...

Страница 14: ...perform steps 6 2 2 and 6 2 3 within 3 seconds 5 1 3 Press the open button The blind will jog 2x to indicate the top limit is cleared 5 1 4 Release the manual control button 5 2 1 Deselect all Group n...

Страница 15: ...position which is set at 50 open by default Setting a new FAVOURITE position overwrites any previous setting 5 2 2 Press and hold the manual control button 5 2 3 Press the close button The blind will...

Страница 16: ...n stop close arrow down and the arrow up buttons to move the blind to the desired favourite position 6 1 2 Press and hold the stop button for 6 seconds DO NOT select a group on the remote Keep pressin...

Страница 17: ...e motor direction is reset The default FAVORITE position will be at 50 after limits are set 6 1 4 Press the heart button The blind will jog 2x to indicate the favourite position is set 6 1 5 Release t...

Страница 18: ...7 2 Release the manual control button after the third jog The Network ID Group assignments and end Limits have been cleared Page 18 of 18 version 1 0...