 RAIN SENSOR 

INSTALLATION CARD

Introduction

In most installations, the Mini-Clik acts as a switch that breaks the circuit to  
an irrigation system's solenoid valves in response to rain. This allows the 
timer to advance as scheduled, but keeps the valves from opening the 
water flow. Once the Mini-Clik has dried sufficiently, the switch closes again 
to allow normal operation.

The Mini-Clik has 25' (8 m) of cable attached to it. The cable terminates 

with blue leads. These leads will be wired to the SEN terminals or SEN and 
SEN COM terminals of the controller. The order in which they are wired 
does not matter (Figure 1).

For the conduit model, Mini-Clik-C: This rain sensor unit is the same as the 
standard model, except there is no aluminum mounting bracket and a 1/2" 
threaded cap that allows for electrical conduit to totally enclose the wires 
has been added. Unless local code states otherwise, plumbing-grade PVC 
pipe can be used, as well as electrical-grade conduit.

Mounting

Standard Model

Using the screws provided, mount the 
Mini-Clik on any surface where it will be  
exposed to unobstructed rainfall, but not in  
the path of sprinkler spray. The switch-housing 
portion must be upright (Figure 2), but the 
swivel bracket can be moved for mounting on 
any angled surface. Loosen the locknut and 
screw before swiveling the bracket, and then 
re-tighten.
For model Mini-Clik-C: The conduit acts as the 
mounting support for the unit. Therefore, place 
and mount the conduit to allow for the desired 
sensor location as described in the main
 instructions for the standard model. Be sure to 
support the conduit sufficiently along its various lengths.

Helpful Hints for Mounting

A.  When looking for a suitable location (such as on the side of a building  
  or post), the closer the Mini-Clik is to the controller, the shorter the    
  wire run will be. This will minimize the chance for wire breaks.

B.  The ideal location for mounting is not always the most practical  

 

  location. In the case where a compromise must exist (such as a low    
  location on a side wall rather than a preferred higher location), note   
  that the Mini-Clik will still work because it will always receive some    
  rainfall — it just will not be as accurate in its gauging as it could be.

C.  As described in the “Operation” section of this manual, “reset  

 

  rate” refers to the amount of time it takes the Mini-Clik to dry  

 

  out sufficiently for the sprinkler system to be allowed to come  

 

  back on. The mounting location will affect this rate and must  

 

  be taken into consideration should extreme conditions exist.  

 

  For example, mounting the Mini-Clik on a very sunny, southern end   
  of a building may cause the Mini-Clik to dry out sooner than desired.  
  Similarly, mounting on the northern end of a building with constant    
  shade may keep the Mini-Clik from drying soon enough.

Once the Mini-Clik is mounted, run the wire to the controller. Fasten it 
every few feet with wire clips or staples for best results. If an extension 
to the wire provided is needed, use the following table to determine the 
minimum wire gauge needed:

If the extension needed is: 

use:

Wiring to Your Irrigation System

IMPORTANT:

 The standard model Mini-Clik is sold and designed for 

hooking up to 24-volt irrigation controllers only. For wiring to 110- or 
220-volt irrigation controllers, consult your distributor or the  
factory. All wiring must conform to National Electrical Code or  
applicable local codes.
For model Mini-Clik-C: WARNING! This unit is designed to be installed 
in conjunction with 24 VAC circuits only. Do not use with 110 or 220 VAC 
circuits. 

Other Controllers

The two most common situations are shown below. For non-standard 
wiring situations, consult your distributor or request our non-standard 
wiring information packet.

X-CORE

®

PRO-C

®

HCC

HC

PRO-HC

ACC2

Figure 1

Figure 2

ACC

I-CORE

®

24VAC

SEN

REM

C

24 V

AC

24 V

AC

GND

SEN-1

SEN

 COM

SEN-2

S1

S1

S2

S2

C

C

GND AC1 AC2 REM C P/MV

SEN
SEN

AC2
AC1
GND

+

+

+

+

24

SEN1

SEN1

SEN2

SEN2

SEN3

SEN3

SEN4

SEN4

VAC

COM

TEST

SEN

SEN

REM

24VAC
24VAC

GND

ICC2

24V
24V
SENSOR 1
SENSOR 2
COMMON

SEN C

SEN 2

SEN 1

REM

24VAC
24VAC

GND

24VAC

COM

P/MV3

COM

 + SEN1

SEN1 –

 + SEN2

SEN2 –

 + SEN3

SEN3 –

 0–100' (15–30 m)

 18 AWG (1 mm)

  >100' (>30 m)

 16 AWG (1.3 mm)